IMG STAGELINE CRAB-12RG Manual De Instrucciones página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
tance of 50 cm to the projection surface and
never cover the air vents of the housing.
1) Set up the unit with its stand and mount-
ing bracket (3) or suspend it to the ceil-
ing or wall. The mounting bracket can be
fixed to a wall hook or screw head at the
wall or ceiling via the hole at its lower
side (4).
Align the unit to the projection surface
by changing its inclination.
2) Connect the power supply unit provided
to the lateral jack DC 5 V (10) and to a
mains socket (230 V~/50 Hz).
5 Operation
1) To switch on, set the sliding switch (8) to
position 2. The fan (7) will start.
2) If no laser beams are emitted, check the
button "Music /Auto" (6) and disengage it,
if necessary.
3) Set the rotating speed of the laser dots
or figures with the control "Motor Con-
troller" (5).
4) To activate the flash feature, set the slid-
ing switch (8) to position 1. Set the flash
frequency with the control "Stroboflash
Controller" (9).
WARNING Please note that fast
changes in lighting, e. g.
flashing light, may trigger
epileptic
photosensitive persons or
persons with epilepsy!
5) To activate the music control, engage the
button "Music /Auto" (6). Adjust the vol-
ume of the music system in such a way
that the laser beams will start flashing to
the rhythm of the music picked up via the
microphone (1). Reduce the distance
between the laser unit and the speakers,
if necessary.
All rights reserved by MONACOR
instruction manual may be reproduced in any form or by any means for any commercial use.
seizures
with
INTERNATIONAL GmbH & Co. KG. No part of this
®
6) After operation, switch off the unit with its
sliding switch (8) [position 3].
Important: The unit is not designed for
permanent operation. After 2 hours of
permanent operation it must be switched
off so that the laser can cool down.
If the laser unit is not in use for a longer
period of time, disconnect the power
supply unit from the socket; even with
the laser unit switched off, the power
supply unit will have a low power con-
sumption.
6 Specifications
Laser wavelength/power
CRAB-12RG, CRAB-22RG
green laser: . . . . . . . 532 nm / 30 mW
red laser: . . . . . . . . . 660 nm / 30 mW
CRAB-12B
blue laser: . . . . . . . . 445 nm/300 mW
Laser class: . . . . . . . . 2M
Projection angle: . . . . ±45°
Power supply: . . . . . . . 5 V via power
Ambient temperature: . 0 – 40 °C
Dimensions: . . . . . . . . 138 × 136 × 110 mm
Weight: . . . . . . . . . . . . 480 g
Note: Due to high light output, the laser diodes
are exposed to considerable stress and there-
fore have a limited life only. Laser diodes are
considered wear parts and are not covered by
guarantee.
Subject to technical modification.
supply unit pro-
vided and con-
nected to 230 V~ /
50 Hz
GB
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Crab-22rgCrab-12b38.571038.572038.5700

Tabla de contenido