CD Player Insertion Module
These instructions are intended for experts (instal-
lation) and for users without any specific technical
knowledge (operation) . Please read these instructions
carefully prior to installation /operation and keep them
for later reference .
All control elements and connections described
can be found on page 2 .
1 Applications
This CD player insertion module is specially designed
as a retrofit for the active speaker systems TXA-800
and TXA-1020, but the module can also be installed
into a different unit .
2 Important Notes
The module (including remote control) corresponds
to all relevant directives of the EU and is therefore
marked with
.
The module must only be installed by qual ified
personnel!
The module is suitable for indoor use only . Protect
it against dripping water and splash water, high air
humidity and heat (admissible ambient temperature
range: 0 – 40 °C) .
For cleaning only use a dry, soft cloth; never use
water or chemicals .
No guarantee claims for the module and no liabil-
ity for any resulting personal damage or material
damage will be accepted if the module is used for
other purposes than originally intended, if it is not
correctly installed or operated, or if it is not repaired
in an expert way .
If the module is to be put out of operation
definitively, take it to a local recycling plant
for a disposal which is not harmful to the en-
vironment .
3 Installation
Always switch off the unit into which the module
is to be inserted and disconnect it from the mains!
3.1 Installation into TXA-800 / TXA-1020
1) Unscrew the cover of the insertion compartment
(underneath the receiver module) .
2) Connect the 5-core cable in the compartment (core
colours: operating voltage = red, black; audio = red,
black, white) to the jack of the CD player module .
Note: The cable, wrapped around a ferrite core, may slip
out of the compartment and attach itself to the speaker
magnet . It this case, unscrew the POWER switch module
underneath the compartment, if necessary .
3) Insert the CD player module into the compartment
and fasten it with screws . If the POWER switch mod-
ule was unscrewed (see above), fasten it again .

3.2 Installation into a different unit

In order to make sure that the module also complies
with the EMC (electromagnetic compatibility) direc-
tive during operation, connect the audio output via
shielded cables . Non-compliance with the EMC
directive will invalidate the declaration of conformity .
1) For installing the module into the basic unit, a cut-
out of 171 × 41 .5 mm is required . The mounting
depth is 190 mm . The module must be installed
horizontally .
2) Connect the module via the 5-pole jack (see fig . 3
on page 2) .
Pin
Audio output
L
left channel
G
ground
R
right channel
The current consumption is 1 A max . and 10 mA min .
(with the player switched off) .
3) Insert the module into the cutout on the basic unit
and use four screws to fasten it via its front plate .
Specifications
Power supply
Audio output
Dimensions (W × H × D)
Weight
4 Operation
The player allows to replay standard audio CDs and
CDs, USB storage media and SD / SDHC memory cards
with MP3 files .
Notes
1 . Depending on the CD type, the CD burner and the burn-
ing program used, problems may occur when CD-RWs
are replayed .
2 . The player also supports the reproduction of WMA files .
3 . Due to the large number of storage device manufacturers
and device drivers, it cannot be guaranteed that all storage
media are compatible with this player .
4 . Cigarette smoke and dust will easily penetrate through all
openings of the player and also settle on the optics of the
laser sampling system . If this deposit causes reading errors
and sound interruptions, the player must be cleaned by
skilled personnel . Please note that there will be a charge
on cleaning, even during the warranty period!
5 . The anti-shock memory of the player will be able to com-
pensate temporary shocks or vibrations occurring during
the CD sampling; however, it will not be able to compen-
sate continuous, severe vibrations . For CD operation, the
unit must therefore always be operated in a stationary
way, i . e . it must be placed on a solid, immobile surface .
Pin
Operating voltage
ground
+
+12 V
⎓ 12 V, 1 A
950 mV
190 × 42 .5 × 190 mm
1 kg
7