• Duration can be set at 8 to 15 seconds. Selecting a time longer than 10 seconds will allow more accurate results to be
obtained.
• After the test has been completed, the frequency analysis chart will be displayed for RPM calculation; then the trend of the
battery voltage recorded during the test will be shown.
• A bar chart will be displayed on the left; it will allow the voltage drop per cylinder (in green) and the power absorbed per
compression (in yellow) to be analysed.
• Press "FORWARD"; two more windows – absorbed power and relative compression – will be shown.
Displayed POWER is the power absorbed by the starter when compression takes place; it shows the force exerted by the starter
and the pressure reached in the cylinders.