Fuel; Main Principles Of Operation; The First Commissioning - Viadrus AGURO Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
Don't touch the outer surfaces of the stove – danger of burning and possible life danger, except of control and regulating
elements!
Never extinguish fire in the pellet stove by water!
Ash from the ash-pan has to be removed carefully and with using of protective equipment, and only when the pellet stove is out
of operation!
Put ash into inflammable vessels with a cover!
The consumer mustn't be used for combustion of waste, rubbish; and no liquid fuels can be used in any combination! Use only
recommended fuels.
In case of occurrence of a fire of deposits in the chimney, extinguish quickly the fire in the stove by a dry-power extinguisher or
by sand, remove all flammable material situated near the stove and the chimney body. Close the door, control elements of the
stove and the smoke regulating shutter (if it is installed) and immediately announce the fire to a fire-fighting service!
Ensure performance of inspection of the pellet stove and flue-gas channel, including the chimney by a qualified person before
repeated commissioning!
It is not allowed to perform any modification of the product, except of mounting and service works performed by qualified
persons.
It is possible to use only spare parts approved by the manufacturer for repairs.
In case of non-observance of these conditions, a user loses a right to guarantee repairs.
5.3

Fuel

The guarantee of clean and good combustion is the using of only dry and naturally stocked wood. Fuel is to be stocked in a dry place.
The stove is determined for firing of high-quality wooden pellets; combustion of, for example, wood chips, straw or corn is not
allowed. Don't use pellets manufactured from different materials than pressed wooden matter (for example, from olives, corn, flax,
etc.)
Pellets have to comply with at least one of the following directives or norms:
Directive No. 14-2000 of the Ministry of Environment of Czech Republic
DIN 517 31
ÖNORM M 7135
Prescribed granularity of pellets
Water content in fuel
Ash content
ATTENTION!
Bad fuel quality can significantly negatively influence the power and emission parameters of the stove.
Quality wooden pellets usually have a smooth sheeny surface, the uniform length and the low share of dust. Low-quality pellets have
longitudinal and transverse cracks, the non-uniform length and the high share of dust. Pellets quality can be also checked by an easy test. Insert
some pellets into a glass with water. If the pellets quality is good, then they will sag down to the bottom, and if their quality is worse, then they
will swim on the water surface.
However, the precisely fuel quality can be only determined with help of proper analyzing devices.
During filling-up pellets into the fuel reservoir, be care about not to contact bags with pellets with the hot surface of the stove.
5.4

Main principles of operation

The stove and its operation is controlled automatically, by means of an electronic system. The stove cannot be overloaded (from the point
of view of power), if it is operated in accordance with the instructions manual. Don't operate the stove with non-prescribed fuel (ref.
chapter 5.3). Combustion of other than prescribed fuel and non-observance of the above mentioned conditions can bring to a damage of
components inside the stove or the entire stove and to canceling of validity of the warranty.
Remove ash from the heating chamber and ash-pan before each kindling.
In case of season using and at insufficient draught and atmospheric conditions it is necessary to be very careful during commissioning.
After long-term interruption of operation, it is necessary to carry out a check that the flue gas channel is not impacted.
We recommend before each season to perform maintenance, including cleaning according to chapter No. 7.
The stove is equipped with a system for automatic cleaning of the burner bowl during operation. This cleaning is set in the system to one
time per hour for the period of 30 sec. The flue exhauster will be switched on to the maximum rotation speed, by which the burner bowl
will be blown-over in order to prevent obstruction of holes for supply of combustion air on the bottom surface of the bowl. That's why don't
be surprised, when this activity automatically occurs during operation.
5.5

The first commissioning

At the first kindling, because of burning-in of the surface painting of the pellet stove, it is necessary to ventilate
constantly and supply enough quantity of fresh air to the room!
Before the first commissioning, it is necessary to remove labels and withdraw parts of accessories from the ash-pan or from the
combustion chamber; this rule is also valid for a possible transport stopper.
Check a right placement of the burner.
Close the door of the combustion chamber.
Fill up the bunker by normative wooden pellets (Ø 6 mm).
Connect the power supply cable.
Switch over the main switch to the position "1".
In case that your house has mechanical ventilation and there is low pressure inside, open the window near the stove for some minutes till
flame burn up.
6 to 8 mm
max. 12 %
max. 1,5 %
85