3.2 BOILER FIXING

To fit the burner to the boiler it is necessary to carry out the following:
Widen, if necessary, the insulating gasket holes (3, fig. 3).
Fix the flange (5) to the boiler door (1) using four screws (4) and (if necessary) the nuts (2) interposing
the insulating gasket (3) but keep unloosing one of the two upper screws (4) (see fig. 2).
Put on the flange (5) the burner combustion head, tighten the flange with the screws (6) and lock the
loose screw (4).
N.B.: The burner can be fixed with the variable dimension (A) (see fig. 4). Anyway, make sure that the
combustion head crosses completely the boiler door thickness.
Fig. 2
3.3

PROBE-ELECTRODE POSITIONING

ATTENTION
Ensure that the plate (3, fig. 5) is always inserted
in the flattening of the electrode.
Lean the probe insulator (4) against the cup (2).
915T1
916T1
TYPE
17
A
3083
S7002
917T1
918T1
30
31
31
TYPE
A
915 T1
116 - 70
916 T1
114 - 100
917 T1
128 - 110
918 T1
167.5 - 145
3.5
±
0.3
3
6
GB
Fig. 3
D5012
A
Fig. 4
D5011
Fig. 5
2
A
±
0.3
1
4
D6088