Release the exhaust filter and clean it
using the cleaning tool.
Refit the exhaust filter into the cover.
Place the pre-filter onto the exhaust
filter.
The filter unit is complete.
Carefully refit the filter unit on the
dust box and clip the filter unit into
position.
The exhaust filter must be replaced
with a new one after approx.
6 months in order to achieve the best
possible cleaning results.
Cleaning the side brushes
Clean the side brushes as required. For
this you will require the cleaning tool
which is located at the top of the dust
box lid.
Place the robot vacuum cleaner up-
side down on a level, clean surface.
Using both hands, take hold of 2 op-
posite elastic side brush holders and
pull them upwards to remove them.
Remove threads and hair using the
wiper which is located on the bottom
of the cleaning tool.
Hold the wiper over a bin.
Press the button at the top of the
wiper several times until all threads
and hair have fallen out.
Press the cleaned side brushes care-
fully onto their pins until they audibly
engage. Take care to comply with the
markings L and R.
In order to continue to achieve the
best possible cleaning results, re-
place the side brushes with new
ones after approx. 1 year.