● No cooling:
Check the power supply for power cut; burnt-out fuse; plug not fitting in the socket or wrong Voltage.
● Lamp not working:
The lamp may have burnt out. If this happened replace it with a 10W/115V lamp.
● Deterioration of cooling performance:
Check that the setting on the thermostat knob is not too warm, that the door is closed properly, that
thick layers of ice have not built up in the freezer, that the door isn't being opened too frequently,
that too much food hasn't been placed in the refrigerator or that food which is too warm is not being
placed in the refrigerator.
● Stop working:
Check if there is a power failure, power voltage is low excessively, power plug make contact well
and temperature regulator points to position "0".
● Food frozen in cold-storing chamber:
Check if the temperature control dial may set too big, and if the stowed food contact with the cold source of cabinet
back.
● The water overflowed after defrosting:
Check that the drain hole is not blocked, and the drain pan is fixed properly.
● Normal phenomena:
1.
Dew may appear on the exterior of the refrigerator if the external humidity is high. This
can be wiped dry.
2.
The area where the door seal sticks to the refrigerator may be warm. This is caused by
the heating device to avoid dew and frost.
3.
A bubbling/ rattling noise sometimes could be heard. This is due to refrigerant flowing in
the cooling pipe or because the refrigerator is in start-up or closing mode.
4.
The temperature of the compressor can reach 80
O
C.