3M Speedglas 9100 Instrucciones De Uso página 11

Ocultar thumbs Ver también para Speedglas 9100:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 65
1 ï
Replacement of welding filter
The welding filter can be removed and replaced according to figure C:1
and E:1 - E:2.
Replacement of inner protection plate
The welding filter must be removed to replace the inner protection plate.
The used inner protection plate is removed as illustrated in figure D:1. The
new inner protection plate should be inserted after the protective film is
removed as illustrated in figure D:2.
Magnifying lens (accessory) mounting (see figure D:3).
Replacement of batteries
The welding filter must be dismounted from the welding shield to access
the battery compartments. Take out the battery holders (use a small
screwdriver if necessary). Insert new batteries in the battery holders
according to figure G:1. Slide each battery holder into the welding filter
until it snaps in position. Note that all settings will be reset to the original
manufacturing setting.
Speedglas 9100V and Speedglas 9100X has a solar panel (see fig A:3) to
assist the batteries.
Replacement of headband
The headband can be replaced according to figure F:1-F:2.
Replacement of sweatband
The sweatband can be replaced according to figure F:3.
CAUTION
The used batteries/worn out product parts should be disposed of according
to local regulations. The welding filter should be disposed of as electronic
waste.
Extended coverage
Extended head and neck cover (accessory) mounting (see figure H:1 –
H:2).