RH430, RH440
Control element
No. in
Description
fig. 1, page 3
1
Temperature controller
6

Installation

!
WARNING!
Damage to the refrigerant circuit at the back of the cooling device
causes a fire hazard as the cooling agent is highly flammable. To avoid a
damage to the refrigerant circuit due to instability of the cooling device,
always fix the cooling device in accordance with the instructions.
A
NOTICE!
When carrying the cooling device handle it with special care.
• Carry the cooling device with two people.
• Only carry the cooling device upright.
• Be careful not to damage the technical components located at the
backside.
The cooling device is designed for free-standing installation, but can be built-in if the
following conditions are complied with to ensure satisfactory operation and maxi-
mum cooling efficiency.
• The cooling device must be levelled carefully to ensure proper function.
• For the glass door version: When ambient humidity is above 65 % in 25 °C ambi-
ent temperature, moisture will condense on the door.
• The socket outlet for the mains connection must be freely accessible.
• When the cooling device is positioned, the supply cord must not be trapped or
damaged.
Ventilation (fig. 3, page 4)
• Ventilation must be provided as shown in alternatives A, B, C or D.
• Ventilation grills (1), if used, must have openings of at least 200 cm² each.