Ideal LANTEK 6 Manual De Manejo página 336

Tabla de contenido

Publicidad

POWER-UP
Press the On/Off
key to turn on the DH
TESTER FIELD CALIBRATION
1. Connect the channel adapters to the DH and RH.
2. Power both units on.
3. Connect one of the two appropriate patchcords to the
adapters of the DH and RH units.
4. From the DH Ready screen, select Field Calibration.
5. From the Field Calibration screen, select Start.
6. At completion of the first patchcord process, disconnect
the first patchcord from the adapters of the DH and RH
and insert the second patchcord into both of the units'
adapters.
7. Select Start.
8. At completion of the second patchcord process, the field
calibration is complete and you are ready to set up your
unit to perform tests.
Please note:
1.
Field calibration is necessary weekly and every time the type of
patchcord changes.
2.
It is not necessary to do a field calibration at every measurement.
SETTING AUTOTEST PREFERENCES
1. From the DH Ready screen, select Preferences.
2. Select Autotest Preferences.
3. From this screen, set the following preferences:
Simple Cable ID
Pass Fail Icon
Stop on Fail
Autosave
Include and Save Graphs
Auto Increment
Marginal pass/fail
ACR
Resistance
Capacitance
Impedance
Enable 24 ELFEXT
© 2002 IDEAL INDUSTRIES, Inc., Part No. 6510-30-0400 Rev. A
PERMANENT LINK TEST SETUP
1. Attach the channel adapters to both the Display and
Remote Handsets.
2. Attach the appropriate patchcords (2 meter) to the
adapters.
3. On the horizontal cable to be tested, disconnect the
corresponding user patchcords from the network patch
panel and the RJ-45 or Tera wall outlet.
4. Connect the DH with the adapter and the appropriate
patchcord end to the network patch panel, and then
connect the RH with the adapter and the appropriate
patchcord end to the wall outlet.
CHANNEL LINK TEST SETUP
1. Attach the channel adapters to both the Display and
Remote Handsets.
2. On the link to be tested, disconnect the corresponding
user patch (up to 5 meter) cords from the network
equipment.
3. Connect the DH adapter to the patch panel using the
user patchcord and the RH adapter to the wall outlet
using the user patchcord.
PERFORMING AUTOTEST ON A TWISTED PAIR CABLE
The selection of cable type determines the default tests
included in an Autotest suite.
1. Press Shift and Setup simultaneously or select Cable
Type on the DH Ready screen to choose the cable type
from the following:
Twisted Pair Permanent
Ethernet
Twisted Pair Channel Link
Custom Cable
Miscellaneous Types
Fiber
2. Select a standard or predefined cable to set the tests to
perform and pass/fail limits.
3. Press Autotest to begin testing. The cable tester will
perform a predefined test suite.
4. The test result is displayed below the Title Bar at the top
right corner of the screen.
PASS/FAIL REPORTING
Overall Autotest Results
Overall test result is a pass.
Overall test result is a fail.
Individual Autotest Results
All values pass with sufficient margin.
One or more values fail.
* or
* - pass or fail by a small margin.
STORING TEST RESULTS
1.
Select Stored Results on the DH Ready screen and
press Enter. At this point, you will see a list of all jobs
which are currently available. If you have never created
a Job, the list will be empty.
2.
To create a new Job select
screen appears.
3.
Use the Arrow keys to select New Job.
Press Enter. The New Job screen appears.
4.
Type a name into the text field on the New Job screen
using the alphanumeric keyboard. Press each key a
second or third time to select the second or third
character on the key.
5.
After entering the name, press Enter. You will return to
the Job Options screen where you can Access Job
information, Delete Jobs, Rename Jobs, make a Job the
current Job, or create more Jobs. The new active job
name is displayed at the top left corner of the display.
RUNNING AN ANALYZE TEST
1. On the DH Ready screen, select Analyze to open the
Analyze screen. The Analyze screen lists the tests that
can be performed on the currently selected cable type.
2. Press the Arrow keys to highlight the desired test.
3. Press Enter to start the test.
4. Upon test completion, a tabular results screen is
displayed.
IDEAL INDUSTRIES (U.K.) Ltd.
IDEAL INDUSTRIES GMBH
Europe Boulevard
Gutenbergstr. 10
225, Gemini Business Park
85737 Ismaning
Warrington WA5 7TN
GERMANY
UNITED KINGDOM
Tel : +49-89-99686-0
Tel : +44-1925-444446
Fax : +49-89-99686-111
Fax : +44-1925-445501
http://www.idealindustries.com
. The Job Options

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lantek 7

Tabla de contenido