Fig. 16
A
1.
Adjust the position of the burn chamber in relation to the
surround.
2.
The front of the burn chamber must be flush with the front
of the layer.
The gap below the decorative frame must be 5 mm parallel
3.
to the second layer on the top (Fig. 16 A) This can be adjusted
with the foot screws (Fig. 16 B).
4.
Level the burn chamber.
Fig. 17
Use bracket 5 (Fig. 17 A) on layer 3 and 4.
1.
2.
Adjust the brackets with bare hands if necessary to make
them hold the stones together.
Fig. 18
1.
Place the attachment bracket on the special corner stone
223628 (Fig. 18 A). The front stone (Fig. 18 B) of layer 5 shall
rest on the attachment bracket.
B
A
B
A
223628
Fig. 19
A
Install the flue pipe. Top smoke outlet (Fig. 19 A) or rear
1.
smoke outlet (Fig. 19 B). If a rear smoke outlet: Remove the
knockout in the rear plate (Fig. 19 C).
Fig. 20
F
E
D
B
A
If top smoke outlet:
Place the last layer (Fig. 20 A) and the top layer (Fig. 20 B).
1.
Use bracket 2, bracket 4 and bracket 6 between the last layer
and the top layer (Fig. 20 C).
Remove the knockout and place the top grid (Fig. 20 D).
2.
Place the distance pieces (Fig. 20 E), remove the knockout
3.
and place top heat shield (Fig. 20 F).
If rear smoke outlet:
Place the last layer (Fig. 20 A) and the top layer (Fig. 20 B).
1.
Use bracket 2, bracket 4 and bracket 6 between the last layer
and the top layer (Fig. 20 C).
Place the top grid (Fig. 20 D).
2.
Place the distance pieces (Fig. 20 E) and place top heat shield
3.
(Fig. 20 F).
ENGLISH
B
C
C
47