Remote Control

The infrared remote control provided is supplied
with a battery inserted . Prior to the first opera-
tion, remove the insulating foil from the battery
support on the rear side of the remote control .
When pressing a button, always direct the
remote control towards the infrared sensor (14)
on the unit . There must be no obstacles between
remote control and sensor .
The following buttons of the remote control can
be used like the buttons on the unit:
OPEN / CLOSE (23) [corresponds to button
FOLDER (25)
PITCH BEND (26)
MT (27)
PITCH (28)
PLAY / PAUSE (29)
CUE (30)
PROG . (31)
CD / USB (32)
The buttons SINGLE / CONT (33), TIME (34) and
SKIP
❙◀
/
▶❙
(35) can be used with limitations
like the buttons on the unit CONT . / LIST (6),
TIME / TAG (5) and SKIP
❙◀
/
▶❙
(18):
– The button SINGLE / CONT can only be used
for switching over the operating mode;
it is not possible to load play lists .
– The button TIME can only be used for swit-
ching over the time indication;
it is not possible to switch over the ID3 tag
indication .
– The SKIP buttons
❙◀
/
▶❙
of the remote control
can be used like the buttons on the unit for
selection of titles, folders, play lists and par-
titions; for fast selection keep the respective
button pressed .
However, the buttons cannot be used in com-
bination with other buttons .
The numerical keys (24) and the SCAN buttons
◀◀
▶▶
and
(36) can be used as an alternative
to the buttons on the unit:
– The numerical keys can be used instead of the
SKIP buttons to select titles, folders, play lists
and partitions . The selection is made by the
input of the corresponding number . In case
of numbers of several digits, press the corre-
sponding numerical keys one after the other,
e . g . the buttons "1" and "0" for number 10 .
◀◀
▶▶
– The SCAN buttons
and
forward and reverse: As long as the respective
SCAN button is kept pressed, the title is played
forward or backward .
If the remote control is not used for a longer
period of time, remove the battery so that the
remote control will not be damaged if the bat-
tery should leak .

6.1 Battery replacement

If the range of the remote control decreases, the
battery must be replaced .
1) Press the locking of the battery support to the
left (1
st
arrow in fig . 8) and at the same time
remove the support downwards (2
Fig. 8 Battery replacement
2) Remove the old battery and insert a new
(3)]
one (3 V button cell, type CR 2025) . Ensure
that the positive pole of the battery shows
upwards in the support .
3) Slide back the support into the remote con-
trol .
Used batteries must not be placed
in the household waste; always take
them to a special waste disposal, e . g .
collection container at your retailer .
7

Updating the Firmware

If a new firmware (operating system of the unit)
is available on the Internet, the firmware of your
unit may be updated:
1) If a firmware update for the CD-196USB is
offered on the home page of IMG STAGE-
LINE (www .imgstageline .com), download
and copy it onto a USB memory stick .
2) Switch off the CD / MP3 player with the power
switch (12) .
3) Insert the USB memory stick with the new
firmware version into the USB port (2) .
4) Keep the button PROG . (7) pressed and
switch on the unit again . Do not release the
button PROG . until "UP dA t E" is shown on
the display .
5) After reading in, when "Ready" appears in
the text line (N), press the button
to start the firmware update . By means of
the bar graph indication (H) and the text line
the update can be observed . When "Finish"
is shown, the firmware has been updated .
6) Switch off the player and switch it on again .
Attention: The firmware update is made at your
own risk . After the update the way of functi-
oning of the unit may be different from that
serve for fast
described in this manual .
All rights reserved by MONACOR
may be reproduced in any form or by any means for any commercial use.
nd
arrow) .
2 .
1 .
▶❙❙
(19)
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual
8

Maintenance of the Unit

Protect the unit from dust, vibrations, humidity
and heat . For cleaning only use a dry, soft cloth,
never use water or chemicals .
Note concerning sound interruptions and
reading errors:
Cigarette smoke and dust will easily penetrate
through all openings of the unit and also settle
on the optics of the laser sampling system . If this
deposit should cause reading errors and sound
interruptions, the unit must be cleaned by skilled
personnel . This cleaning will be charged, even
during the warranty period!
9
Specifications
Frequency range: . . . . . 20 – 20 000 Hz
THD: . . . . . . . . . . . . . . . < 0 .1 %
Channel separation: . . . > 75 dB
Dynamic range: . . . . . . . > 80 dB
S / N ratio: . . . . . . . . . . . > 75 dB
Outputs
LINE OUT: . . . . . . . . . . 2 V
DIGITAL OUT: . . . . . . . 0 .5 Vpp S / PDIF
USB standard: . . . . . . . . 2 .0
Readable file systems: . . NTFS, FAT, HFS+
Max . number of
partitions: . . . . . . . . . . 16
folders: . . . . . . . . . . . . 999 per partition,
in 8 levels max .
MP3 files: . . . . . . . . . . 999 per folder
Anti-shock memory
standard audio CDs: . . 8 s
MP3 files: . . . . . . . . . . 10 s
Power supply: . . . . . . . . 230 V/ 50 Hz
Power consumption: . . . 15 VA
Ambient temperature: . . 0 – 40 °C
Dimensions: . . . . . . . . . 482 × 90 × 270 mm
(W × H × D),
2 RS (rack spaces)
Weight: . . . . . . . . . . . . 4 .4 kg
Connections
USB input: . . . . . . . . . type A
analog output: . . . . . . RCA Left / Right
digital output: . . . . . . RCA
fader start: . . . . . . . . . 3 .5 mm connector
Subject to technical modification .