Example Of Typical Use Of The Interface/Repeater Unit - Velux KLF 100 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Example of typical use of the interface/repeater unit

thermostatic control of a vELUX skylight by a
compatible thermostat
A thermostat can be used to control automatic opening
and closing of skylight(s) depending on the temperature. A
typical thermostat works by means of a dry change-over
contact that switches between two positions depending
on the ambient temperature.
The illustration shows how to connect the dry change-
over contact to the interface/repeater unit.
A thermostat set to 72°F/22°C will typically change
position (ie open the skylight(s)) when the temperature
rises above 74°F/23°C, and switch back (ie close the
skylight(s)) when the temperature has again fallen below
70°F/21°C.
The skylight(s) can be operated with the remote control
at any time.
ENGLISH
C
˚F
72°F/
22°C
~74°F/
~70°F/
23°C
21°C
VELUX 13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Klf 100 3lf s01 us/au

Tabla de contenido