Toyotomi TAD-T35 Manual De Instrucciones página 6

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7. TRANSPORTATION
Preferably keep the unit in the vertical position during transporta-
tion. If it is necessary to place the unit in a horizontal position for
more than 1/2 hour, ALLOW IT TO REMAIN UPRIGHT FOR 24
HOURS BEFORE OPERATION. Failure to do so may result in dam-
age to the compressor. Before transporting/moving the unit make
sure the drain tank is empty.
8. TROUBLESHOOTING SYMPTOM CAUSE SOLUTION
SYMPTOM
CAUSE
Unit does not
• Power cut.
work.
• The plug has been
plugged improperly.
• The full-tank indicator
is ON. Tank is full.
Unit suddenly
• The indoor tempera-
stops during
ture has reached the
in operation.
set temperature level.
• The preset time is up.
• The full-tank indicator
is ON. Tank is full.
Unit runs in-
• Malfunction.
termittently.
• Surrounding tempera-
ture is too high or too
low.
• Exhaust duct hose is
blocked.
Unit func-
• Window or door is left
tions but the
open in the room.
room is not
• There is heat source in
cooled.
the room or too many
of people in it.
• Air in take grille is
clogged.
• Filter is too dirty.
• Temperature setting is
too high.
Condensed
• The tank is nearly full.
water is
spilled out
when moving
the unit.
LCD display
• The temperature sen-
shows "E1".
sor error.
LCD display
• The coil sensor error.
shows "E2".
BEFORE CALLING FOR SERVICE
The followings are not defects.
A hissing noise or hollow
sound :
A squeaking noise :
Odor :
The unit does not start nor
change operation mode
immediately :
SOLUTION
• Wait for Power to be
supplied again.
• Plug in again.
• Remove the drain wa-
ter.
• Reset the temperature
level.
• Reset the timer.
• Remove the drain wa-
ter from the drain tank
• Contact your dealer.
• Check the duct hose.
• Close all windows and
door.
• Move out any heat
source in the room.
• Clean the air intake
grille.
• Replace the filter.
• Lower the temperature
setting.
• Remove the drain plug
on the rear bottom of
the unit, drain off the
water then the unit will
be in operation auto-
matically.
• Contact your dealer.
• Contact your dealer.
This sound is generated from the
refrigerant flowing within pipes.
This noise is generated from the
unit when it is expands or con-
tracts with temperature changes.
Such odor as tobacco, cosmetics,
or foods may accumulate in the
unit.
To prevent overloading the com-
pressor motor, the unit will be
stopped for more than 3 minutes.
9. SPECIFICATIONS
MODEL
COOLING CAPACITY
DEHUMIDIFYING CAPACITY
(26.7°C / 60%)
POWER SOURCE
POWER CONSUMPTION
OPERATING CURRENT
AIR FLOW (MAX.)
OPERATING TEMP. RANGE
DIMENSIONS (W × H × D)
WEIGHT
COMPRESSOR
REFRIGERANT
NOTE: Cooling air capacity will vary according to temperature and
humidity of the room.
10. VENTING KIT ACCESSORIES
If the unit is to be used exclusively in one space, the cooling effi-
ciency will be enhanced by using the following venting kit accesso-
ries.
EXHAUST DUCT SET (FLEXIBLE TUBE) (Fig. I)
INTAKE DUCT SET (FLEXIBLE TUBE) (Fig. I)
WINDOW PANEL KIT (Fig. J)
USING EXHAUST AND INTAKE DUCT SET (Fig. I)
1.
Connect the duct hose adapter nozzle (I1), and duct hose grille
(I2) to 2 sides of exhaust hose (I3) to create an exhaust assembly.
2.
Connect the duct hose adapter nozzle (I4), and duct hose grille
(I5) to 2 sides of intake hose (I6) to create an intake assembly.
Sliding in one end of hose assembly (with Duct hose adapter
3.
nozzle) to rear panel (B2) and turn knob
embly firmly.
4.
Sliding in one end of hose assembly (with duct hose adapter
nozzle) to rear panel (B3) and turn knob
embly firmly.
NOTE:
Place the unit as close as possible to the window or
door.
USING WINDOW PANEL KIT (Fig. J)
NOTE:
Window installations are possible by the use of the duct set
and window planel kit.
1.
Insert the window panel extension (J2) to both end of window
panel (J1).
2.
Open the window and place window panels into window.
Adjusting to fix the length of window panels by using the scr-
ews and wing nuts mounted on both ends of window panel (J1).
3.
Insert the other end of exhaust and intake duct hose assembly
(with duct hose grille) onto window bracket (J1).
4.
Please allow 20 in. (50 cm) of space around the unit for proper
air circulation.
5.
When removing the portable air conditioner for storage, the
window panel may be left in place. Simply place the cover (J3)
over the hole on the window panel.
NOTE:
The same procedure can be adapted for vertical in-
stallation in sliding windows.
OPTIONAL ACCESSORIES
When you need a longer size window panel, please purchase the
extension window panel and use it with the original window panel.
Part # 22741086 Extension window panel "B" (S) 28-3/8" (72 cm)
3
ENGLISH
TAD-T35
12,000 BTU/h (ASHRAE - 128 standard)
7,500 BTU/h (DOE - 2017 standard)
0.43 gal/h (1.65 L/H)
Single Phase 115V, 60Hz
1,050 W
9.5 A
188 CFM (320 m³/h)
64°F-95°F (18°C-35°C)
18-1/8" x 29-1/4" x 16-15/16"
(460 × 742 × 405 mm)
74.0 Lbs (28.8 kg)
ROTARY
R-410A
Max. 4 ft. (1.2m), Dia. 6 in. (150 mm)
Max. 4 ft. (1.2m), Dia. 5 in. (130 mm)
For sliding and double-hung windows
Max. 37 in. (94cm)
Min. 20 in. (50cm)
to fix the hose ass-
to fix the hose ass-

Publicidad

Tabla de contenido
loading

Tabla de contenido