Maintenance of the roof air conditioner

!
WARNING! Health hazard
Any other maintenance work to that which is described here may only
be carried out by qualified personnel who are familiar with the risks
involved when handling refrigerant and air conditioning systems as well
as the relevant regulations.
Interval
Inspection/maintenance
Regularly
Check the condensation water drainage:
➤ Check whether the condensation water drainage channels
Clean the filter of the air discharge unit (fig. 7, page 7):
Regularly
➤ Manually take off the filter cover (1).
➤ Remove the filter (2).
➤ Clean the filter (2) with a detergent solution and let it dry.
➤ Put the dry filter (2) back in.
➤ Put the cover (1) back on.
Once per year
Check the profile seals:
➤ Check the seal between the roof air conditioner and the roof of the
Once per year
Have the heat exchanger serviced:
➤ Have the heat exchanger of the roof air conditioner serviced by
Replace the carbon filter (fig. 7, page 7):
Once per year
➤ Manually take off the filter cover (1).
➤ Remove the filter (2).
➤ Remove the carbon filter (3).
➤ Clean the filter (2) with a detergent solution and let it dry.
➤ Put a new carbon filter in.
➤ Put the dry filter (2) back in.
➤ Put the cover (1) back on.
EN
(fig. 6 1, page 6) at the sides of the roof air conditioner are clear
and the condensation water is able to escape.
vehicle for cracks and other damage.