Fermax CITYLINE DUOX Serie Manual De Instalador Y Usuario página 32

Kit audio
Ocultar thumbs Ver también para CITYLINE DUOX Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DUO
DUO
X CITYLINE KIT 1-2L
X CITYLINE KIT 1-2L
DUO
DUO
DUOX CITYLINE KIT 1-2L
X CITYLINE KIT 1-2L
X CITYLINE KIT 1-2L
DUO
DUOX CITYLINE KIT 1-2L
DUO
X CITYLINE KIT 1-2L
X CITYLINE KIT 1-2L
X CITYLINE KIT 1-2L
DUO
DUO
X CITYLINE KIT 1-2L
A)
CN1
Connection call extension module, keypad.
B)
CN9
Tamper Connection (via 2mm male Stocko connector).
C)
DL2
Mode Led:
• Slow flash (2 blinks / 3 sec): Guard Unit Day or Mixed Mode.
• Slow flash (1 blink / 1 sec): Inverse or Sequential Programming. See DUOX Advanced
Programming Manual cod. 97699.
• Off: Guard Unit Standby or Night mode.
D)
MASTER Panel:
Programming is always done from the panel activated as MASTER.
EAny installation can only have one MASTER panel at a time, whether a single or
multiple block installation, once configured as a sub-block, block or general entrance.
An entry panel is configured as a MASTER via the SW1 amplifier button. If the SW1
button is pressed 3 times quickly, it is activated as a MASTER panel and a
confirmation tone sounds (beep-beep).
When a panel is selected as MASTER, it notifies the rest of the situation and if
another was previously configured, it would automatically stop being so.
If there are various blocks in an installation, we recommend using the general
entrance panel as MASTER since it allows you to program all of its telephones.
Once having completed the terminal´s configuration, we recommend deactivating
the MASTER panel to avoid accidentally reprogramming terminals.
The panel deactivates itself from master mode following the same activation
procedure: 3 quick presses of the SW1 button. A deactivation tone sounds (beep-
bop).
Configuration - Programming the Amplifier
The DUOX amplifier can be configured to allow for the operation as a general entrance,
block entrance or sub-block entrance.
The DUOX system uses 6 digit house terminal addresses.
These call code digits are organised as follows: BBSSNN:
- BB: indicates the Block number, (from 00 to 99).
- SS: indicates the sub-Block number, (from 00 to 99).
- NN: indicates the sub-Block house number, (from 00 to 99).
You do not have to segregate the installation according to this hierarchy since the system
adapts to the installation´s needs.
Pag 8

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Cityline duox 1lCityline duox 2l

Tabla de contenido