RESTORE DEFAULT VALUES: RESET

The DUOX amplifier has a 'Reset' function which can be used to restore programmed
default parameters.
RESET Mapping (call button code)
1.- Reset amplifier: remove power.
2.- Press the SW1 button, connect power supply and keep SW1 button pressed until you
hear the reset confirmation sound: beep-beep (5 seconds).

Lock Release Times Programming

There are two programmable lock-release activation times:
- Lock-release time set from the residence.
- Lock-release time set from the exit button (connected to the 'BS' and '-' terminals).
Carry out the following steps:
1.
With the power supply disconnected, short circuit the «Bs» and «-» (negative) amplifier
terminals (or press the exit button when one exists).
2.
Maintaining the short-circuit induced above, connect the system's power supply (at this
point it will no longer be necessary to maintain the short circuit or hold down the
button). At this time the amplifier will ''beep'' for every second
been pro-grammed for from the residence.
2.1.If you want to change this value, you must press any call button as often as the
seconds you wish to program.
2.2.If you do not want to change, just wait 5 seconds without pressing any call button.
3. Thenthe amplifier will ''beep'' for every second the opening time has been programmed
from the exit button.
3.1.If you want to change this value, you must press any call button as often as the
seconds you wish to program.
3.2.If you do not want to change, just wait 5 seconds without pressing any call button.
4. Exit Programming:
To exit programming mode, wait 5 seconds without pressing any key. A «beep beep»
tone will sound to indicate that you have exited time programming mode.
Notes:
• Values:
- Lock-release time:
- Exit button time:

RESET to default parameter values (via keypad)

You can Reset the parameters to the factory default values. For this you must temporarily
connect a keypad (ref. 7439) to enter the numeric values. Download the Direct Panels
Programming Manual, cod. 97701 at www.fermax.com.
Pag 10
01..99 sec. (Default: 03).
00..99 sec. (Default: 06).
the opening time has

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Cityline duox 1lCityline duox 2l

Tabla de contenido