INSTALLATION

Electrical Connection

1
2
1. Temperature/Pressure relief valve
2. Hot water outlet
3. Cold water inlet
4. Discharge pipe
Install a discharge pipe from the relief valve terminating
at a sink or drain. Orient the tubing so that discharge will
exit within 6˝ (152 mm) above or at any distance below the
structural floor, and cannot contact any live electrical parts.
DO NOT CAP OR THREAD THE END OF THE DISCHARGE PIPE,
IT MUST BE UNOBSTRUCTED AND FULL SIZE.
The T&P valve is certified by a nationally recognized test
laboratory that maintains periodic inspection of the listed
equipment, and meets the requirements for relief valves and
automatic shut-off devices for hot water supply systems ANSI
Z21.22.
The T&P valve is marked with a maximum pressure, which
does not exceed the maximum working pressure of the water
heater (150 PSI).
THE DISCHARGE PIPE
- Must not be smaller in size than the outlet pipe size of
the valve, or have reducing couplings.
- Must not be plugged or blocked.
- Must be of material suitable for hot water.
- Must not be over fifteen feet (15 ´ ) in length.
- Must not have more than two elbows.
- Must terminate at an adequate drain.
- Must not have a valve between the relief valve and the
tank.
9.1

Filling the Water Heater

To fill the water heater:
1. Open the hot water faucet.
2. Open the cold water supply valve.
3. When water runs out of the faucet, the tank is filled.
4. Close the hot water faucet.
www.stiebel-eltron-usa.com
5. Manually vent the T&P valve. See 12.2, "Venting the
T&P relief valve", pg. 8
6. Check entire system for leaks.
3
10. Electrical Connection
CAUTION:
!
4
ALWAYS FILL THE UNIT'S TANK WITH WATER BE-
FORE PLUGGING THE WATER HEATER'S CORD INTO
AN ELECTRICAL OUTLET. FAILURE TO DO SO WILL
RESULT IN PERMANENT DAMAGE TO THE WATER
HEATER.
NOTICE:
THE WATER HEATER MUST BE CONNECTED TO A
GROUNDED OUTLET.
THIS WATER HEATER WAS DESIGNED FOR USE AT
110 - 120 V. DO NOT USE THIS WATER HEATER WITH
ANY OTHER VOLTAGE. FAILURE TO USE THE COR-
RECT VOLTAGE MAY RESULT IN PERSONAL INJURY
OR PROPERTY DAMAGE.
THE HEATER IS SUPPLIED WITH AN ELECTRICAL
CABLE WITH A PLUG. IF THE CABLE IS DAMAGED OR
LENGTH NOT SUFFICIENT, IT MUST BE REPLACED BY
A LICENSED ELECTRICIAN.
To be certain that all the air is out of the system, open the
hot water faucet on your fixtures until constant water flows
from them. Otherwise, damage to the device may occur.
Connect the water heater to a GROUNDED OUTLET.
The unit is fitted with a power cord to connect the water
heater to a receptacle. State and local codes must be adhered
to. Install the correct breaker at the circuit breaker panel.
The water heater was manufactured and wired in accordance
with the UL requirements.
A temperature high limit with manual reset has been facto-
ry installed to interrupt the power supply in the event of a
thermostat failure.
DO NOT use this water heater with any other voltage. Failure
to use the correct voltage may result in personal injury or
property damage.