Description; Technical Data - SKF TWIM 15 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32

3. Description

The operation of the heater is controlled by the
internal electronics in two modes.
The operator can either select the desired
temperature of the bearing in Temperature Mode or
set the length of time that the bearing or component
will be heated in Time Mode. The power level can
be adjusted to Low Power Mode for slower heating
of sensitive workpieces (for example, bearings with
shields or metallic inserts in the seals).

3.1 Technical data

Designation
Max. bearing weight *
Min. bearing bore diameter
Max. bearing outer diameter
Max. bearing width
Performance examples
(bearing, weight, temperature, time)
Maximum power
Voltage
Max. current consumption
Temperature control
Demagnetisation
Dimensions (w × d × h)
Total weight
* Depending on the geometry of the bearing, maximum heating temperature and power availability.
6
EN
TWIM 15/230V, TWIM 15/110V
20 kg (44 lb)
20 mm (0.79 in)
320 mm (12.6 in)
85 mm (3.35 in)
6320: 7,1 kg (15,7 lb), 110 ˚C (230 ˚F), 320 seconds
22320 CC/W33: 12,8 kg (28.2 lb), 110 ˚C (230 ˚F), 755 seconds
TWIM 15/230 V: 2,3 kVA
TWIM 15/110 V: 1,8 kVA
TWIM 15/230 V: 230 V, 50 Hz
TWIM 15/110 V: 110 V, 60 Hz
TWIM 15/230 V: 10 A
TWIM 15/110 V: 16 A
20 - 200 ˚C (68 - 392 ˚F)
The heater does not magnetise
450 × 500 × 100 mm (17.7 × 19.7 × 3.9 in)
6,6 kg (14.6 lb)

Publicidad

Tabla de contenido
loading

Tabla de contenido