Errors and faults

The accurate functionality of the device was tested
during production a number of times. However, if
functionality faults do occur, then check the device
according to the following list.
The device does not start:
• Check the mains power
(230 V/1~/50 Hz).
• Check the mains plug for damages.
• Have the electrics checked by a specialist com-
pany for cooling and air-conditioning or by
®
TROTEC
.
The device runs but forms no condensation:
• Check the condensation tank is positioned correct-
ly. Check the fill level of the condensation tank and
empty it if necessary. The condensation tank indi-
cator light must not light up.
• Check the float in the condensation tank for dama-
ges. If necessary, clean the float and condensation
tank. The float must be able to move freely.
• Check the room temperature. The working range
of the device is between 5 °C and 35 °C.
• Ensure that the relative humidity complies with the
technical data (min. 40 %).
• Check the set operation mode. The humidity in the
room must be above the selected range. If neces-
sary, turn the rotary switch (11) to the right to
"Continuous" (13).
• Check the air filter is not dirty. If necessary, clean
or replace the air filter.
• From the outside, check the condenser is not dirty
(see chapter "Maintenance"). If your condenser is
dirty, have it cleaned by a specialist company for
cooling and air-conditioning or by TROTEC
The device is loud or vibrates; condensation leaks:
• Check whether the device is standing upright and
on an even surface.
The device gets very warm, is loud or is losing
B - 9
performance:
• Check the air inlets and air filter are not dirty. Re-
move external dirt.
• Check the inside of the device and especially the
fan, the fan housing, the evaporator and the con-
denser for external dirt (see chapter "Maintenan-
ce"). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and
air-conditioning or by TROTEC
Your device still does not operate correctly after
these checks?
Bring the device to a specialist company for cooling
and air-conditioning or to TROTEC
®
.