Ground Screw (Green)
Terminal Block Screw
Neutral-Ground Jumper Wire
(Green)
Power Cord Ground Wire (Green)
A1. Remove the green ground screw connecting the neutral-ground jumper wire
(green) to the cabinet and the center terminal block screw, then discard the
jumper wire.
A2. Attach the power cord ground wire (green) to the cabinet with the green ground
screw. Tighten the screw securely.
A3. Attach the power cord neutral wire (white) with the center terminal block screw.
Tighten the screw securely.
A4. Attach the remaining 2 power cord line wires (red and black) with the outer
terminal block screws. Attach one wire to each terminal block as shown. Tighten
both screws securely.
IMPORTANT: Do not make a sharp bend or crimp the wires at connections.
PART B - 3-WIRE POWER CORD
A
B
C
Ground Screw (Green)
Terminal Block Screw
Neutral-Ground Jumper Wire
(Green)
B1. Attach the power cord neutral wire (white) to the center terminal block screw.
Tighten the screw securely.
B2. Attach the remaining 2 power cord line wires (red and black) with the outer
terminal block screws. Attach one wire to each terminal block as shown. Tighten
both screws securely.
IMPORTANT: Do not make a sharp bend or crimp the wires at connections.
Power Cord Neutral Wire (White)
Power Cord Line Wires (One Red;
One Black)
Power Cord
D
E
F
Power Cord Neutral Wire (White)
Power Cord Line Wires (One Red;
One Black)
Power Cord
17