3 Operating / 4 Miscellaneous
GB
3 Operating
1. Connect the power plug to a mains socket.
2. Turn on the device by pressing the on-/off button 6 .
NOTE
For choosing operating time observe instructions of the
acrylic liquid or gel manufacturer.
3. Press timer button 7 .
> UV light bulbs get switched on and light up.
> LED „90 Sec" indicates a 90 seconds operation time.
•
If you press timer button 7 again, operation time is increased: 120
seconds, 30 minutes, 60 minutes. LED 1 , 2 , 4 and 5 indicate your
choice.
4. There are three ways to switch off light:
a. While beeing in mode "permanent operation", press timer button 7 .
(To switch the lamps back on press 7 again.)
b. UV light bulbs automatically get switched off when timer has elapsed.
(To switch the lamps back on press 7 again.)
c.
Press on-/off button 6 to switch off the device completely.
> The device is only switched off completely if power indicator LED 3
goes out. Disconnect the power plug from the mains socket.
4 Miscellaneous
4.1
How to
replace
uv light
bulbs
16
•
Disconnect the power plug from the mains socket and wait for the
device and uv light bulbs to cool down.
•
Pull the extendable baseplate 0 out the device.
•
Pull the uv light bulb 8 out of the lamp socket 9 . Pess the new uv
light bulb into the socket until it audibly clicks into place.
•
Push the extendable base plate 0 back into the device.