INSTALLATION IN EXISTING CONSTRUCTION (
WALL INLET INSTALLATION (
A
I
M
TTACHING THE
NLET
When the wiring is complete, assemble the inlet cover to the
tube guard and mounting plate. Insert the top screw through
the entire inlet assembly until the screw engages the mounting
plate.
AO0043
C
I
A
OMPLETING
NLET
SSEMBLY
Once you have attached the
mounting plate to the flexible
tubing, pull the low voltage wire
through the top wiring hole in
the mounting plate.
I
I
NSTALLING THE
NLET
When you place the inlet into
the wall cutout, the mounting
plate and tube guard slip inside
the wall; the inlet cover remains
on the outside.
Holding the inlet assembly
between
your
thumbs
fingers, angle the bottom of the
mounting plate into the cutout.
Push the assembly downward
until you have clearance at the
top of the cutout.
Push the top of the mounting
plate into the cutout and lift the
assembly upward until the top
screw seats in the predrilled
hole. At this point, the wall
should be sandwiched between
the mounting plate and the
frame plate.
CONT
P
(
'
OUNTING
LATE
CONT
D
AR0034
INLET
AE0024A
AO0044
and
AO0046
AO0045
'
)
Insert the bottom screw into
D
the inlet cover and through the
other parts. Give the screw a
)
few turns until it firmly engages
in the mounting plate. Now,
level and slightly lower the
assembly. Make sure the wall is
sandwiched between the inner
and outer parts—you'll be able
to feel if mounting plate is firmly
centered on the inside of the
wall.
Hold the inlet in place and
gradually tighten down each
screw a little bit at a time. (If you
completely tighten down one
screw at a time, the mounting
plate may pull away from the
wall at the loose end and slip
back into the cutout.)
Complete all your wall inlet installations in this manner. If your
cutouts are accurate, each wall inlet will install more quickly
and easily.
360 SERIES INLETS
MOUNTING
PLATE
(CF361 OR CF361F ROUGH-IN)
NOTE: If 330 wall inlet is being used refer to Model 330 Series
Wall Inlet on next page.
B
If area is clear, cut an inlet opening in the wall approximately
18" above the floor. Make sure wall opening and 2½" tube
hole line up (see figure below).
AD0062
16
'
)
CONT
D
AO0047
AR0035
1
3
/
"
16
9
2
/
"
16
1
2
/
"
2
18"