„ Turn on the water supply.
ƒ Turn on the water supply at the stop valves and inspect all the
connections for any leaks (see Ill. 1).
„ Flow Rate Adjustment.
ƒ IMPORTANT: The EcoPower Automatic Faucets must be used
with the stop valves fully opened whenever possible. Insuffi-
cient flow rate will result in power shortage and consumption of
the built-in backup battery.
ƒ If flowrate adjustment is necessary because the wash basin
is too small or the water pressure is too high, turn the stop
valve(s) clockwise to limit the flow. Confirmation of wash basin
specifications is highly recommended before installation of the
Automatic Faucet.
„ Temperature Adjustment (thermal mixing models only).
ƒ The water temperature has been factory set at 100°F (38°C,
Max: 42°C ± 3°C). Depending on the supply water pressure and
other local conditions, the water temperature may not be kept
as specified. In such a case, adjust the temperature by turning
the temperature control handle (see Ill. 2).
ƒ NOTE: If turning the temperature control handle changes the
temperature opposite of the direction indicated, make sure the
hot water supply is connected to the left inlet bracket.
„ Spout and Sensor
ƒ IMPORTANT! Do not scratch the sensor when cleaning the
spout (see Ill. 1).
ƒ Avoid using any cleaning materials that may scratch the spout
surface.
ƒ Never use polishing powder, detergent that includes coarse
particles, thinners, benzene, acids, alkaline detergents, or nylon
scrub brushes, as they can damage the surface of the spout.
ƒ To safely clean the surface, wipe it using a dampened soft cloth
with diluted dishwashing detergent and dry it with another soft
cloth. If this does not adequately clean the surface, wipe the
area with a neutral detergent and wet cloth.
„ Drain (Ryohan only)
To remove the drain cup for cleaning (see Ill. 2):
1. Pull the drain cup unit firmly to the drain part, then release it.
2. Turn the drain cup unit clockwise 45 degrees.
3. Pull the drain cup upwards and out.
NO TE: If the drain cup unit does not come out, put it back and
while turning it clockwise once again, slowly pull it out.

Testing and Adjustment

CARE & CLEANING
8
Ill. 1
Close
Open
Ill. 2
Temperature
Control
Hot
Handle
Cold
Cold
Ill. 1
Ill. 2
Stop Valve
Hot
Temperature
Control
Handle
Sensor
Area
Outlet
Sensor
area
Outlet
Drain
Cup
Unit
Main
Drain
Body

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido