2.4 Electrical connection
Follow the information and instructions contained in this document and
the functional description of the respective control unit. Refer to the
safety recommendations (see section 1).
If the protective conductor connection is not properly made or damaged,
dangerous live voltages may occur on the unit!
The units must only be connected to the power supply by competent
personnel, in conformance with the local connection conditions and
regulations. Improperly connected equipment may lead to serious
personal injury and damage to property.
2.4.1 Electrical specifications
Item
LAGD 1000A/DC.
LAGD 1000A/AC.
1
Fuse according to DIN 72581 T.3
2
Lead: Cross-section 1,5 mm2, length ≤12 m (39.4 ft)
2.4.2 LAGD 1000/DC
The LAGD 1000/DC is supplied with level monitoring as standard. One electrical power
connection is required.
14
Rated
Typical power input
voltage
(load dependent)
24 V DC
0,5 A
230 V/50 Hz
0,45 A
230 V/60 Hz
0,66 A
115 V/50 Hz
1,0 A
115 V/60 Hz
1,3 A
Starting
Back-up
current
fuse
(ca. 20 ms)
ca. 1,4 A
3,0 A
-
2,5 A
-
2,5 A
-
2,5 A
-
2,5 A
SKF LAGD 1000
1
2