Maintenance And Repair; Spare Parts And Accessories - SKF LAGD 1000 Serie Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 110
The counter can display a maximum of 99,999.9 hours. The smallest storable interval is
0,1 hour = 6 minutes. The memory cannot be erased.

6. Maintenance and repair

Carry out the following maintenance and inspection works at regular intervals:
Check level in reservoir
Check the plant components for leakage at regular intervals
Check the bearings visually for a proper lubricating condition
Check electrical cables for damage
Check electrical connections and contacts
Check the basic function of the control unit and system components by initiating an
intermediate lubrication cycle
Check electrical connections in case of fault messages
Replace defective fuses only by new equivalent fuses.
Any works beyond the above-mentioned scope must only be performed by
approved SKF service personnel. Replenish with clean grease only. The
service life of the pump and lubricated machine elements is dependent on the
cleanness of the lubricants used.

7. Spare parts and accessories

Item
Description
Contents
* This item is supplied standard with all LAGD 1000 series lubricators.
SKF LAGD 1000
Metric Connection Kit
LAGD 1000-M
Plastic pipe 50 m (164 ft)
11 x Straight connectors
M10x1
11 x Right angle swivel
connectors M10x1
1 x Connection bar
140 X Cable tie
Imperial Connection Kit*
LAGD 1000-G
Plastic pipe 50 m (164 ft)
11 x Straight connectors G
11 x Right angle swivel
connectors G
/
1
8
1 x Connection bar
140 X Cable tie
/
1
8
31

Publicidad

Tabla de contenido
loading

Tabla de contenido