Components Required For Operation; Intended Use Of Battery-Powered Clipping Machine Fav5 Cl/Fortis; Intended Use Of Charger Gt203/Li-Ion Battery Gt201; Operating Principle Of The Battery- Powered Clipping Machine Fav5 Cl/Fortis - Aesculap Suhl FAV5 CL/FORTIS Instrucciones De Manejo

Ocultar thumbs Ver también para FAV5 CL/FORTIS:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 52
Aesculap Suhl GmbH
Battery-powered clipping machine FAV5 CL/FORTIS
Note
The blade GT330 #10 (USA+UK) for battery-powered
clipping machine FAV5 CL/FORTIS is included in the
scope of delivery. Various blades are available for dif-
ferent applications!

2.2 Components required for operation

• Battery-powered clipping machine FAV5 CL/FORTIS
• Blade
• Charger
• Mains power cord (with device plug)
• Li-ion battery
2.3 Intended use of battery-powered
clipping machine FAV5 CL/FORTIS
The battery-powered clipping machine FAV5 CL/FOR-
TIS is used for shearing small animals.
The battery powered clipping machine FAV5 CL/FORTIS
is used with a blade to be selected according to the
respective application.
2.4 Intended use of charger GT203/Li-
ion battery GT201
The charger GT203 is used for charging the battery-
powered clipping machine FAV5 CL/FORTIS and the Li-
ion battery. There is one charging bay each for the two
components.
2.5 Operating principle of the battery-
powered clipping machine FAV5 CL/
FORTIS
The battery-powered clipping machine FAV5 CL/FOR-
TIS is switched on (off) by pushing the ON/OFF switch
up (down).
4
2.6 Operating principle of charger
GT203/Li-ion battery GT201
The charger GT203 is designed for the mains voltage/
frequency range 100 V to 240 V / 50 Hz to 60 Hz.
To make the charger GT203 ready for operation, con-
nect it to mains power by plugging in the mains plug.
The charger GT203 is equipped with to charging bays.
The first charging bay is for charging the battery-pow-
ered clipping machine FAV5 CL/FORTIS, while in the
second charging bay the Li-ion battery is charged.
Each charging bay has an indicator field on the charger
front panel assigned to it.
Charging starts automatically, as soon as a Li-ion bat-
tery is inserted in the charging station.
The charging time in the charging bays depends on the
charge state and capacity of the Li-ion batteries.

2.6.1 Charging principle

The Li-ion batteries are charged by constant current
pulses.
The charge state of the Li-ion battery is monitored
during charging. Monitoring of the charging curve
ensures that the battery is fully charged without over-
charging.
Additionally, the battery temperature and charging
time are monitored as well.
The charger monitors the battery status and indicates
the charge state via two LED indicators.
LED indicators:
• green = Battery fully charged
• red = Battery completely discharged

2.6.2 Charging time

Charging is stopped as soon as the maximum charging
time is reached.
The charging time is approx. 50 min.

Publicidad

Tabla de contenido
loading

Tabla de contenido