SYSTEM CHECK-OUT

After completing the installation, the fan can be tested for function by
starting the engine with no air in the system. The fan should operate
immediately after the engine is started and should stop as the air
pressure builds up over 80 psi. As soon as the air system reaches
governor cut-out pressure, before the engine reaches operating
temperature, shut off the engine and check for air leaks. If it is
desired to check the fan at operating temperature, it may be
necessary to cover the radiator temporarily and run the engine at fast
idle until operating temperature is attained.

Thermo-Pneumatic Control Valves

Used in all fan clutch installations and
controls the fan clutch. Closing temperature
should be 10° higher than the engine
thermostat (fully open position).
Closing
Temperature
185°
190°
195°
For further assistance call the
Haldex Technical Services
Department @ 800-643-2374.
Brake Systems Division
North American Headquarters
10930 N. Pomona Avenue
Kansas City, Missouri 64153-1297
(816) 891-2470
Fax: (816) 891-9447
Rev. 7/02 1.7M ART L31109
Vehicles With Shutters and Air Conditioning Condenser
(Fig. 19).
1. Thermo-pneumatic Control Valve, normally open, setting
10° above shutter control valve (see Fig. 20 for P/N
identification).
2. Overrirde Sensor Switch, normally open, setting 250 psi.
3. 12 volt Solenoid Valve, normally open, with exhaust
feature.
4. Fittings, tubing, wiring, etc., as required.
5. Install per diagram (Fig. 19).
Part No.
RF36029
RF36030
RF36031
North American Sales and Service Org.
SOLENOID
VALVE
THERMO-PNEUMATIC
CONTROL VALVE
AIR FROM
RESERVOIR
SHUTTER
CONTROL
VALVE
ENGINE
BLOCK
*
*
FAN CLUTCH
REQUIRED
NEW PARTS
Brake Systems Division
10707 NW Airworld Drive
Kansas City, MO 64153-1215
Phone: (816) 891-2470
Fax: (816) 880-9766
www.hbsna.com
FREON
COMPRESSOR
ON/OFF
SHUTTERS
*
OVERRIDE
SENSOR
SWITCH
AIR
CYLINDER
CONDENSOR
RADIATOR
FIGURE 20
Brake Systems Division
Haldex Limited
525 Southgate Drive, Unit 1
Guelph, Ontario Canada N1G 3W6
Phone: (519) 826-7723
Fax: (519) 826-9497

Publicidad