Lithium Battery (Lilo/Lipo/Life) Program; Charging Lithium Batteries - Medion Venom Manual De Funcionamiento

Dual 10 amp
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

LITHIUM BATTERY PROGRAM
These programs are only suitable for charging and discharging Lithium batteries
with a nominal voltage of 3.3V, 3.6V and 3.7V per cell. Lithium batteries use a
charge technique termed constant voltage (CV) and constant current (CC). The
charge current varies according to the battery capacity and performance. The
final voltage of the charge process is also very important. It should be precisely
matched to the charge voltage of the battery. They are 4.2V for LiPO, 4.1V for LiIo,
and 3.7V for LiFe. The charge current and nominal voltage as for cell count set on
the charge program must always be correct for the battery to be charged.
To alter a parameter value in the program, press Start/Enter button to make it
flash, then change the value with INC or DEC button. The value will be stored by
pressing Start/Enter button once.
After setting the current and voltage press Start/Enter button for more than 3
seconds to start the process.
Charge current : 0.1-10A, Voltage: 1-6 Series
dual 10 amp
This program monitors the input voltage of the
source. If the voltage drops below the value you
set, the operation forcibly terminates to protect
the input source.
The backlight intensity of the LCD screen can be
adjusted to suit different conditions.
CHARGING LITHIUM BATTERY
The left side of the first line shows the type of
battery you select in the User Set menu. The
value on the left side of second line sets the
charge current and the value on the right side of
second line sets the voltage of the battery pack.
[ 12 ]