PB (LEAD ACID) BATTERY PROGRAM (CONTINUED)
(screen 1 Previous page)
of the battery on the right. The charge current ranges from 0.1-10.0A. The voltage
should match the battery being charged. Start the charge process by pressing
Start/Enter button for more than 3 seconds.
(screen 2 Previous page)
stop charging, press Batt Type/Stop button once.
BATTERY INTERNAL RESISTANCE TEST MENU
TestLix x Internal
Resistance
MeasuringI R
WaitDlease
1:0260 50 044M
1:0390 42 044
BatteryPackIR
231m
dual 10 amp
Set up the charge current on the left and the nominal voltage
The screen shows the real-time progress during charge. To
DISCHARGING PB (LEAD ACID) BATTERY
Set discharge current on the left and the final
voltage on the right. The discharge current ranges
from 0.1-5.0A. To start the process, press Start/
Enter button for more than 3 seconds.
The screen shows the real-time progress during
discharge. You can alter the discharge current
by pressing Start/Enter button once during the
process, using the INC or DEC to change the
setting, and the Start/Enter button to save the
setting.
This function allows the user to check the internal
resistance of lithium batteries. This is helpful as it
allows the user to track the health of the battery
by checking for increased pack resistance as the
battery ages. Attach the cell balance block to the
balance plug on the battery and the main pack
leads to the charger for this test.
Interface of the Internal Resistance Testing.
Press Start/Enter button to start the test.
M
Displays individual cell Internal Resistance (IR)
Press INC button to view total battery pack IR.
Pressing INC again will return to the individual cell IR.
[ 18 ]