CELL TYPE CHARGE PARAMETERS

The chart below has all the basic charge parameters for different cell types. Actual
charge and discharge rates or voltages may vary by manufacturer or recommended cell
performance. Always consult with the manufacturer instructions for your specific battery
for proper charge parameters.
Voltage Level: 1.2V/cell
Allowable fast charge current: 1C~2C
NiCD / NiMH
(Depends on the performance of the cell)
Discharge voltage cut-off level: 0.85V/cell (NiCD), 1.0V/cell (NiMH)
Voltage Level: 3.6V/cell
Max charge voltage: 4.1V/cell
Lilo
Allowable fast charge current: 1C or less
Minimum discharge voltage cut-off level: 2.5V/cell or higher
Voltage Level: 3.7V/cell
Max charge voltage: 4.2V/cell
LiPO
Allowable fast charge current: 1C or less
Discharge voltage cut-off level: 3.0V/cell or higher
Voltage Level: 3.3V/cell
Max charge voltage: 3.7V/cell
LiFe
Allowable fast charge current: 4C or less (e.g. A123M1)
Discharge voltage cut-off level: 2.0V/cell or higher
Voltage Level: 2.0V/cell (Lead-acid)
Max charge voltage: 2.46V/cell
Pb
Allowable fast charge current: 0.4C or less
Discharge voltage cut-off level: 1.50V/cell or higher