LITHIUM BATTERY PROGRAM (CONTINUED)

VOLTAGE BALANCING AND MONITORING DURING DISCHARGE

The processor monitors the voltage of individual cells during storage mode
and discharge of a lithium battery pack. With the balance block attached to the
balance plug of the battery, it will equalize the voltage of each cell during the
storage and discharge function.
If the voltage of any one or more cells varies abnormally during the procedure, it
terminates the process automatically with the error message "Battery Voltage Cell
0668
You can set up the current and the voltage of the
battery pack to be charged. The current will be used
to charge or discharge the battery to reach the
storage voltage.
The screen shows the real-time progress during
storage process. To stop charging, press Batt Type/
Stop button once.

DISCHARGING LITHIUM BATTERIES

The value of discharge current on the left side of
screen may not exceed 1C for a maximum safety
and the final voltage on the right should not be
under the voltage level that is recommended by the
battery manufacturer to avoid deep discharging.
To start the discharge, press Start/Enter button for
more than 3 seconds.
Discharge current: 0.1-5A
The screen shows the real-time progress during
discharge. To stop charging, press Batt Type/Stop
button once.
Low Vol". If this happens, the battery pack contains
the bad cell, or the bad connection of the cable
plug. You can easily know which one cell is bad by
pressing INC button at time of the error message.
The processor detected the voltage of one cell in
the Lithium pack is too low.
In this case, the 4th cell is bad. If there is a
connection break in the cable or plug the voltage
value may show zero.