Additional Functions; Alarm Function - brennenstuhl BCN 1221 Manual De Instrucciones

Ocultar thumbs Ver también para BCN 1221:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 101
Operating Instructions
BCN 1221

4.4 Additional Functions

The CO-detector is provided with the following
additional user-friendly functions:

Alarm function:

This function is used to turn off the alarm for
4 minutes.
Press the "Test/Hush" button on the alarm.
If the CO-concentration reaches 200 ppm (parts
per million), the alarm will reactivate. The detector
returns to normal function automatically in
4 minutes.
If the concentration increases during the mute
function, the function is overridden and the
detector sounds.
ATTENTION: If the CO-concentration is at
200 ppm, the mute function cannot be activated.
Pre- Alarm- Warning:
If the detector detects a CO- concentration of
greater than 40 ppm, the red LED will blink every
8 seconds until the alarm sounds.
Memory function:
If the detector sounds the alarm due to excessive
CO-concentration (except for the test button), the
memory function in the detector is activated and
28

Publicidad

Tabla de contenido
loading

Tabla de contenido