General Warnings - Beretta CIAO S 20 C.S.I. Manual De Instalacion Y Uso

Ocultar thumbs Ver también para CIAO S 20 C.S.I.:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
USER
1A GENERAL WARNINGS
The instruction manual is an integral part of the product and it must
therefore be kept carefully and must accompany the appliance; if the
manual is lost or damaged, another copy must be requested from the
Technical Assistance Service.
Boiler installation and any other assistance and maintenance
operation must be carried out by qualifi ed personnel according
to current local and national regulations.
For installation, it is advisable to contact specialised personnel.
The boiler must only be used for the application foreseen by
the manufacturer. The manufacturer shall not be liable for any
damage to persons, animals or property due to errors in instal-
lation, calibration, maintenance or due to improper use.
The safety and automatic adjustment devices must not be
modifi ed, during the system life cycle, by the manufacturer or
supplier.
This appliance produces hot water, therefore it must be con-
nected to a heating system and/or a domestic hot water mains,
compatible with its performance and output.
In case of water leakage, close the water supply and contact
the Technical Assistance Service immediately.
In case of absence for long periods time, close the gas supply
and switch off the electrical supply main switch. In case of risk
of frost, empty the boiler.
From time to time check that the operating pressure of the
hydraulic system does not decrease under 1 bar.
In case of failure and/or malfunctioning, deactivate the appli-
ance, and do not try to repair or intervene directly on it.
Appliance maintenance must be carried out at least once a
year: program it with the Technical Assistance Service will avoid
wasting time and money.
Boiler use requires to strictly observe some basic safety rules:
Do not use the appliance in any manner other than its intended
purpose.
It is dangerous to touch the appliance with wet or damp body
parts and/or in bare feet.
Under no circumstances cover the intake grids, dissipation grids
and ventilation vents in the installation room with cloths, paper
or any other material.
Do not activate electrical switches, telephone or any other object
that causes sparks if there is a smell of gas. Ventilate the room
by opening doors and windows and close the gas central tap.
Do not place anything in the boiler.
Do not perform any cleaning operation if the appliance is not
disconnected from the main power supply.
Do not cover or reduce ventilation opening of the room where
the generator is installed.
Do not leave containers and inflammable products in the
installation room.
Do not attempt to repair the appliance in case of failure and/or
malfunctioning.
It is dangerous to pull or twist the electric cables.
Children or unskilled persons must not use the appliance.
Do not intervene on sealed elements.
For better use, remember that:
- a periodic external cleaning with soapy water not only improves
its aesthetic aspect but also preserves panelling from corrosion,
extending its life cycle;
- if the wall-mounted boiler is enclosed in pendant furniture, leave
at least 5 cm for ventilation and maintenance;
- installation of an ambient thermostat will favour a greater comfort,
a more rational use of the heat and energy saving; the boiler can
also be connected to a programming clock in order to manage
ignition and switching off during the day or week.
10
2A IGNITION
First ignition must be carried out by personnel from the Technical
Assistance Service. At the same time, if it is necessary to put the
appliance in service again, carefully follow the described opera-
tions.
To start-up the boiler it is necessary to carry out the following op-
erations:
- power the boiler
- open the gas tap present in the system to allow fuel fl ow
- turn the mode selector (1 - fi g. 1a) to the desired position:
Ciao S C.S.I.:
Summer mode: turning the selector to the symbol summer
(fi g. 2a) the traditional function of only domestic hot water is acti-
vated. If there is a domestic hot water request the digital display
shows the hot water system temperature, the icon to indicate the
hot water supply and the fl ame icon
Winter mode: by turning the mode selector within the area mar-
ked + and - (fi g. 2b), the boiler provides domestic hot water and
heating. If there is a heat request, the boiler switches on and the
digital monitor indicates the heating water temperature, the icon to
indicate heating and the fl ame icon (fi g. 3a). If there is a domestic
hot water request, the boiler switches on and the digital display
shows the hot water system temperature, the icon to indicate the
hot water supply and the fl ame icon (fi g. 4a)
Pre-heating (faster hot water): rotate the domestic hot water
temperature adjustment knob (2 - fi g. 1a) to the
(fig. 5a), to activate the pre-heating function. This function
keeps the water in the domestic hot water exchanger hot, to
reduce standby times when a request is made. When the pre-
heating function is enabled, the monitor indicates the delivery
temperature of the heating water or the domestic hot water,
according to the current request. During burner ignition follow-
ing a pre-heating request, the monitor indicates the
(fig. 5b). To deactivate the pre-heating function, rotate the
domestic hot water temperature adjustment knob back to the
symbol. Bring the domestic hot water temperature adjustment
knob back to the required position. This function cannot be activated
when the boiler is OFF: function selector (1 fi g.1a) on
Ciao S R.S.I.:
Summer mode (only with the external water tank connected):
turning the selector to the symbol summer
tional function of only domestic hot water is activated and the boiler
supplies water at the temperature set on the external storage tank.
If there is a domestic hot water request the digital display shows
the hot water system temperature, the icon to indicate the hot
water supply and the fl ame icon
Winter mode: by turning the mode selector within the area marked
+ and - (fi g. 2b), the boiler provides hot water for heating and - if
connected to an external storage tank - domestic hot water. If there
is a heat request, the boiler switches on and the digital monitor
indicates the heating water temperature, the icon to indicate he-
ating and the fl ame icon (fi g. 3a). If there is a domestic hot water
request, the boiler switches on and the digital display shows the
hot water system temperature, the icon to indicate the hot water
supply and the fl ame icon (fi g. 4a).
Adjust the ambient thermostat to the required temperature (~20°C)
Ciao S C.S.I.: Adjustment of domestic hot water temperature
To adjust domestic water temperature (bathrooms, showers, kitchen, etc.),
turn the knob with symbol
The boiler is standby status until, after a heat request, the burner
switches on and the digital display shows the hot water system tem-
perature, the icon to indicate the hot water supply and the fl ame icon
The boiler will be in function until the adjusted temperature is
reached, afterwards it will be in "standby" again.
If the red indicator light near the
lights up, this means the boiler is in temporary stop status (see the
chapter about light signals and faults). The digital monitor indicates
the fault code detected (fi g. 6a).
Ciao S R.S.I.: Adjustment of the domestic hot water temperature
CASE A heating only - adjustment does not apply
CASE B heating only + external storage tank with thermostat - ad-
justment does not apply.
CASE C heating only + external storage tank with probe - to adjust
(fi g. 2a) the tradi-
(fi g. 2b) within the area marked + and -.
symbol on the command panel
symbol
symbol
OFF.

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ciao 24 c.s.i.Ciao s 24 r.s.i

Tabla de contenido