230/208 VOLT ELECTRICAL SUPPLY
HOW TO CONNECT
1 Remove the room cabinet.
2 Connect to electrical power.
3 See the special instructions below for applicable
supply voltages.
4 Reinstall the room cabinet.
A power supply kit must be used to supply power to the
Zoneline unit. The appropriate kit is determined by the
voltage, the means of electrical connection and the
amperage of the branch circuit.
Power supply kit
Connections of 208 or 230 volt circuits may be with a
power supply kit or a junction box kit.
All wiring, including installation of the receptacle,
must be in accordance with the NEC and local codes,
ordinances and regulations. Local codes may require
the use of an arc fault or leakage current detection
device on the power cord. Be sure to select the
correct cord for your installation.
Tandem
Perpendicular
15 Amp.
20 Amp.
230/208 volt receptacle configuration.
Branch Circuit and
Unit Amperage Rating
15
20
30
*Not approved for use on 7000 BTU models.
Installation Instructions
Large Tandem
30 Amp.
Proper GE Power Cord
with LCDI Device
RAK3153
RAK3203
RAK3303*
Power cords may include an arc fault interruption or
a leakage current detection interruption device. A
test and reset button is provided on the plug case or
the inline case. The device should be tested on a
periodic basis by first pressing the TEST button and
then the RESET button. If the TEST button does
not trip or if the RESET button will not stay engaged,
discontinue use of the Zoneline and contact a
qualified service technician.
Order Kit RAK4002A for 230/208 volt direct
connection.
IF USING AN ELECTRICAL
SUBBASE
230/208 volt models may be installed using one of
the following electrical subbases:
Branch Circuit and
Unit Amperage Rating
15
20
30
*Not approved for use on 7000 BTU models.
Electrical subbases provide an enclosure for direct
connection or enclosed receptacles. The subbase kit
includes the power cord.
The instructions provided with the selected subbase kit
must be carefully followed. It is the responsibility of the
installer to ensure the connection of components is
done in accordance with these instructions and all
electrical codes.
14
Proper GE
Subbase Kit
RAK204D15P
RAK204D20P
RAK204D30P*