2-3. Setting up the UPS

Step 1: UPS input connection
Plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension
cords.
 For IEC & LV models: The power cord is supplied in the UPS package.
 For NEMA models HV: The power cord is integrated to the UPS. The input plug is a NEMA
5-15P for E4 VALUE 1000, NEMA 5-20P and E4 VALUE 1500/2000 models.
 For E4 VALUE NEMA 3000 LV & HV, connect the supply wires to the "Input" terminal. A
circuit breaker (40A) must also be installed between the mains and the AC input of the
UPS for the 3KVA NEMA models for safety operations.
Step 2: UPS output connection
To connect directly to the IEC output (IEC or NEMA), simply connect your devices to the
outlets with a M/F cable.
For E4 VALUE 3000 models, if the charge is higher than 10A (IEC) or 15A (NEMA) or if
there is only one output connect into a distribution board :
a) Remove the small cover from the terminal block
b) For the E4 VALUE 3000 IEC or NEMA HV, we recommend the use of an AWG14 or
2
2.5 mm
power cords.
For the E4 VALUE 3000 NEMA LV, we recommend the use of an AWG 2-10 or 4 to 6
2
mm
power cords.
A circuit breaker (40A) must also be installed between the mains and the AC input of the
UPS for the 3KVA NEMA models for safety operations.
c) Upon completion of the wiring connection, please check that the wires are securely
affixed.
d) Put the small cover back on the rear panel.
Step 3: Communication connection
Communication ports:
To allow for unattended UPS shutdown/start-up and/or status monitoring, connect one end of
the communication cable to the RS-232 port and the other to the communication port of your
PC. With the monitoring software installed, you can schedule the UPS shutdown/start-up and
monitor the UPS status on your PC.
Step 4: Turn on the UPS
Press the ON/Mute button on the front panel for two seconds to power up the UPS. Be sure
that green light "On Line" and "Inverter" are lighting.
Note: The battery charges fully during the first five hours of normal operation. Do not
expect full battery run capability during this initial charge period.
Step 5: Install software
For optimal computer system protection, install the UPS monitoring software to fully configure