Control-channel 6 - Shutter, strobe
Decimal Hexad. Percentage S/F
00
0000
0%0%
1128 0180
0%50%
129133 8185
51%52%
134243 86F3
53%95%
244249 F4F9
96%98%
250255 FAFF
98%100%
Control-channel 7 - Focus
Decimal Hexad. Percentage S/F
0255 00FF
0%100%
Control-channel 8 - Effect-wheel
Decimal Hexad. Percentage S/F
07
0007
0%3%
89
0809
3%4%
1033
0A21
4%13%
3461
223D
13%24%
6263
3E3F
24%25%
6487
4057
25%34%
88115 5873
35%45%
116117 7475
45%46%
118141 768D
46%55%
142169 8EA9
56%66%
170171 AAAB
67%67%
172195 ACC3
67%76%
196223 C4DF
77%87%
224225 E0E1
88%88%
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
4) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
S Shutter closed
F Gradual adjustment of the dimmer intensity from 0 to 100 %
S No function (Shutter open)
S Random strobe effect with decreasing speed
F Reset (after 3-5 seconds)
F No function (Shutter open)
S Continuous adjustment from near to far
S Shutter closed
S 3-facet-prism
F Forwards rotation 3-facet-prism with increasing speed
F Backwards rotation 3-facet-prism with increasing speed
S 4-facet-prism
F Forwards rotation 4-facet-prism with increasing speed
F Backwards rotation 4-facet-prism with increasing speed
S 3D-prism
F Forwards rotation 3D-prism with increasing speed
F Backwards rotation 4-facet-prism with increasing speed
S 9-facet-prism
F Forwards rotation 9-facet-prism with increasing speed
S Backwards rotation 9-facet-prism with increasing speed
S Rainbow effect with increasing speed
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
Feature
Feature
Feature
32/64