Troubleshooting - Briggs & Stratton 190477GS Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983

TROUBLESHOOTING

Problem
Engine is running, but
no AC output is
available.
Engine runs good but
bogs down when
loads are connected.
Engine will not start;
or starts and runs
rough.
Engine shuts down
during operation.
Engine lacks power.
Engine "hunts" or
falters.
Briggs & Stratton Power Products Home Generator System
Owners Manual
Cause
1.
Circuit breaker is open.
2.
Poor connection or defective cord set.
3.
Connected device is bad.
4.
Fault in generator.
1.
Short circuit in a connected load.
2.
Generator is overloaded.
3.
Engine speed is too slow.
4.
Shorted generator circuit.
1.
Rocker switch set to "Off".
2.
Fuel valve is in the "Closed" position.
3.
Dirty air cleaner.
4.
Out of gasoline.
5.
Stale gasoline.
6.
Spark plug wire not connected to
spark plug.
7.
Bad spark plug.
8.
Water in gasoline.
9.
Overchoking.
10. Excessively rich fuel mixture.
11. Intake valve stuck open or closed.
12. Engine has lost compression.
Out of gasoline.
1.
Load is too high.
2.
Dirty air filter.
1.
Choke is opened too soon.
2.
Carburetor is running too rich or too
lean.
www.mymowerparts.com
Solution
1.
Reset circuit breaker.
2.
Check and repair.
3.
Connect another device that is in good
condition.
4.
Contact Briggs and Stratton service
facility.
1.
Disconnect shorted electrical load.
2.
See "Don't Overload the Generator" on
page 9.
3.
Contact Briggs service facility.
4.
Contact Briggs service facility.
1.
Set switch to "On".
2.
Turn fuel valve to the "Open" position.
3.
Clean or replace air cleaner.
4.
Fill fuel tank.
5.
Drain gas tank and fill with fresh fuel.
6.
Connect wire to spark plug.
7.
Replace spark plug.
8.
Drain gas tank; fill with fresh fuel.
9.
Set choke to "Off" position.
10. Contact Briggs service facility.
11. Contact Briggs service facility.
12. Contact Briggs service facility.
Fill fuel tank.
1.
See "Don't Overload the Generator" on
page 9.
2.
Replace air filter.
1.
Move choke to halfway position till engine
runs smoothly.
2.
Contact Briggs service facility.