Use as sludge remover
N O T E
• Only use the unit with a filter!
• The operating modes "suction" and "emptying" each last approx. 25 seconds. The unit switches over auto-
matically between the modes. Sequence: The unit is in suction mode. The unit is switched off. The stop
valve at the outlet opens and the dirty water runs out. The unit is switched on again.
How to proceed:
1. Connect the unit to the power supply and switch on.
2. Guide the universal nozzle to the floor of the pond.
3. Move the nozzle with slow and uniform movements to vacuum up the sludge.
– Turn the floor nozzle through 180° to vacuum up thin layers of sludge or to clean rigid preformed pond liners.
4. Switch off the unit after use.

Remedy of faults

Malfunction
The unit does not perform its suction function
The unit does not reach its full capacity
The collection container does not run empty,
the unit does not prime
Low suction capacity

Wear parts

• Filter media
• Valve rubber elements

Maintenance and cleaning

How to proceed:
 D
1. Switch off the unit and disconnect the power plug.
2. Disconnect the hoses.
3. Undo the side locking clips and remove the motor housing.
4. Undo the filter holder.
5. Remove the filter and rinse under running water.
– If the filter is damaged, replace it with an original filter.
6. Clean the container.
7. Clean the bottom of the motor housing.
8. Check the rubber valve in the drain hose and clean.
9. Reassemble the unit in the reverse order.
Cause
Drain hose incorrectly fitted
Excessive height difference between water
level and unit
Dirt has accumulated in the foam filter, in the
suction tube or in the suction hose
Dirt has accumulated in the area of the non-re-
turn valve at the drain hose preventing it from
closing properly
The collection container cannot drain
Collection container and drain hose are soiled
The more tubes are used, the higher the tube
frictional resistance. The suction capacity
reduces.
Remedy
The non-return valve must be located at the
free end of the drain hose
Places the unit at water level height
Remove soiling
Remove soiling
Lay the drain hose without kinks.
Provide slight gravity for the drain hose.
After draining, almost no water should remain
in the collection container.
Remove soiling
Hold the suction hose as flat as possible to im-
prove the suction performance
- EN -
13

Publicidad

Tabla de contenido
loading

Tabla de contenido