Scope of delivery

2.2

Operating the device safely

WARNING!
!
 Do not operate the device in areas with combustible atmos-
pheres.
NOTICE!
A
 Only use the connecting hose included in the scope of delivery.
 Check the connecting hose before every use. Replace the con-
necting hose if it is damaged or soiled with oil.
 Make sure that the refrigerant does not contain large quantities
of oil and is not in the hose in liquid form.
 The initial pressure may not exceed 20.7 bar.
 Replace the filter of the instrument as soon as the connecting
hose is soiled with oil.
 Only connect the analytical device to the low-pressure side of
the cooling system.
 Do not fill liquids or oil-containing refrigerant samples into the
analytical device.
NOTE
I
 Place the device on a stable and and level surface.
 Make sure that the air intake and the ventilation hoses of the
device are free.
3
Scope of delivery
No. in
fig. 1,
Description
page 3
1
Control and display module
2
Low-pressure coupling with filter
3
Manual pump for manual ventilation
4
Connection cable
14
Mini Identifier R-134a