Connecting the inverter
8.3
Mounting the inverter
➤ Hold the inverter against the installation location and mark the fastening
points (fig. 4 A, page 4).
➤ Attach the inverter using your chosen fastening method (fig. 4 B,
page 4).
9
Connecting the inverter
9.1
General instructions
WARNING!
!
The inverter may only be connected by a qualified workshop.
The following information is intended for technicians who are fa-
miliar with the guidelines and safety precautions to be applied.
Never use the inverter on vehicles where the positive terminal
of the battery is connected to the chassis.
If you do not fit a fuse to the positive cable, the cables can
overload, which might result in a fire.
Reversed polarity can damage the inverter.
When installed in vehicles or boats, the inverter must be connected to the
chassis or earth.
When setting up a socket distribution circuit (mains setup), comply with
VDE 0100.
Only use copper cables.
Keep the cables as short as possible (< 1.8 m).
42
SinePower
EN