Connecting The Inverter; General Instructions - Waeco SinePower MSI912 Instrucciones De Montaje

Ocultar thumbs Ver también para SinePower MSI912:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 81

Connecting the inverter

8.3
Mounting the inverter
➤ Hold the inverter against the installation location and mark the fastening
points (fig. 4 A, page 4).
➤ Attach the inverter using your chosen fastening method (fig. 4 B,
page 4).
9
Connecting the inverter
9.1

General instructions

WARNING!
!
 The inverter may only be connected by a qualified workshop.
The following information is intended for technicians who are fa-
miliar with the guidelines and safety precautions to be applied.
 Never use the inverter on vehicles where the positive terminal
of the battery is connected to the chassis.
 If you do not fit a fuse to the positive cable, the cables can
overload, which might result in a fire.
 Reversed polarity can damage the inverter.
 When installed in vehicles or boats, the inverter must be connected to the
chassis or earth.
 When setting up a socket distribution circuit (mains setup), comply with
VDE 0100.
 Only use copper cables.
 Keep the cables as short as possible (< 1.8 m).
42
SinePower
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido