After cleaning and descaling
Insert the pad
• Put the cleaned pad or replacement pad [4] into the hotwater chamber.
Assemble the appliance
• Put the steam tower [3] back into the air humidifier. Press the steam nozzle [1] into the opening at the top
of the steam tower [3].
• Screw the tank catch [9] onto the water tank [8]. Place the water tank [8] in the air humidifier.
• Place the cover [2] on top of the air humidifier.

9. In the event of problems

Problem
No steam exiting
Appliance leaking
Delay in steam output
Red indicator [A] illu-
minated
If the problem persists, please contact customer service.

10. Technical details

Rated output
Nominal voltage
Water tank volume
Evaporation rate
Overheating protection
Safeguard against
running dry
Switching
Weight
Dimensions (W / H / D)
Connection
Cause
Appliance not connected to power.
Water tank [8] empty.
Water tank [8] not fitted correctly.
Water tank [8] leaking.
Water tank [8] not shut properly.
Steam tower [3] not installed or not
installed correctly.
Very cold water in tank.
Appliance heavily scaled.
Water tank [8] empty.
Valve on tank catch [9] is covered with dirt. Clean the valve.
Appliance heavily scaled.
Water tank [8] not shut properly.
Water tank [8] not fitted correctly.
365W
230V / 50Hz
approx. 6 litres
Level I: approx. 200 ml/h
Level II: approx. 400 ml/h
Through thermostat
If there is not enough water in the heater unit, the appliance switches off auto-
matically. The appliance has a sensor which detects the water level.
2-stage
approx. 3.0 kg
310 / 230 / 350 mm
Fixed cable, approx. 1.4 m in length
Remedy
Insert the plug [11] into the mains
and switch on the appliance.
Replenish water.
Fit tank [8] properly.
Replace tank [8].
Fasten the catch [9] properly.
Install steam tower [3] properly.
Use warmer water.
Descale the appliance.
Replenish water.
Descale the appliance.
Close the catch [9] properly.
Fit tank [8] properly.
20