Notes on Approval
A
Notes on Approval
A.1
Marking
TC RU C-DE.BH02.B00456
PO Ex ia I X
0 Ex ia IIC T4/T3 X
Dräger Safety
Type: MQG 0020
23560 Lübeck, Germany
0158
I M1 / II 1G
Um=4.6V Im=1.3A
Ex ia I/IIC T4/T3 Ma/Ga
IECEx BVS 10.0053X
BVS 10 ATEX E 080X
ANZEx 11.2003X
Intrinsically safe Ex ia, CSA 11 1800517
CSA: Class I, DIv. 1, Gr: A,B,C,D TC T4/T3
Class I, Zone 0, A/Ex ia IIC T4/T3 /Ga
Warning: Read manual for safety precautions.
Avertissement: Lire le manuel avant utilisation.
Do not change or charge batteries in haz loc.
1
Serial No.
1
The year of manufacture is indicated by the third letter in the serial number:
Y = 2007, Z = 2008, A = 2009, B = 2010, C = 2011, D = 2012, E = 2013, etc.
Example: Serial No. ARCH-0054: the third letter is C, which means that the
unit was manufactured in 2011.
294
Battery Pack Type ABT 0100
Temperature Class T4
–20 °C  Ta  +50 °C
if used with alkaline batteries
Duracell Procell MN1500
Duracell Plus Power MN1500
Temperature Class T3
–20 °C  Ta  +40 °C
if used with NiMH batteries
GP 180AAHC (1800 mAh)
if used with alkali batteries
Varta Powerone 4006
Varta Powerone 4106
Panasonic Powerline LR6
Battery Pack Type HBT 0000 and HBT 0100
Temperature Class T4
–20 °C  Ta  +50 °C
Dräger X-am 5100