Location
Model BR 102-F is used for wireless interconnection with Brennenstuhl's
model smoke alarm. It is not interconnectable with other brands of smoke
alarms.
BR 102-F shall be installed outside of each separate sleeping area in the im-
mediate vicinity of the beedrooms, and on each additional story of the family
living unit including basements and excluding crawl spaces and unfinished
attics. The recommended additional areas are living room, dining room,
bedrooms(s), attic (finished) utility room, basement and hallaway.
Caution
Research indicates that substantial increase in warning time can be obtained
with each properly installed, additional alarms. It is strongly recommended
that a smoke alarm be located in each room in your house (except the bath-
room) to ensure maximum protection.
Recommended location of Smoke Detectors
G Smoke Detectors for minimum Protection
Smoke Detectors for Additional Protection
G G
Single Floor
Bed-
Bed-
Bedroom
room
room
Bed-
room
Bath-
room
Living room
Kitchen
Figure 1
Location to avoid
• In an area where the temperature may fall below 40° F or rise above 100° F.
• In very humid area of near of bathroom, kitchen, moisture or steam may
cause the unit to false alarm.
• In dead air space.
• The garage – automobile exhaust air may cause false alarm.
10
Ceiling
Best in center
of room
Figure 2
Dead air
space
max 365 cm
Wall
Hall
Bedroom
Bedroom Bedroom
Kitchen
Living room
Basement
Figure 3