The steps for setting, activating and de-activating Alarm 2 are the same, but
using the AL2 button instead of AL1.
SNOOZE SETTING AND STOPPING THE ALARM:
1.
When the alarm is sounding, press any one of the four keys SET, IN, OUT or
SNZ to activate the snooze function. The alarm will stop and re-activate after
the snooze interval of 5 minutes.
2.
To stop the alarm completely, press any one of the four keys AL1, AL2, DATE
or CH.
LCD 3 INDOOR TEMPERATURE AND HUMIDITY READING WITH
COMFORT LEVEL INDICATOR:
Minimum Display
Indoor Temperature
in °C
The indoor temperature and humidity are received automatically and displayed on
the third section of the LCD.
THE COMFORT LEVEL INDICATORS:
A happy face icon " J" indicating a temperature level between
Comfortable:
20ºC and 25°C and humidity between 45% and 65%.
Uncomfortable: A sad face icon " L" indicating any value outside the comfortable
range.
TOGGLING AND RESETTING THE INDOOR RECORDINGS
1.
To toggle between the indoor current, minimum and maximum temperature
and humidity data and the times at which they were recorded, press the IN
key:
Once to show the minimum temperature and humidity values with time and
date recorded.
Twice to show the maximum temperature and humidity values with time and
date recorded.
Three times to return to the current time, date, temperature and humidity
levels.
2.
To reset the minimum and maximum temperature and humidity data and the
times at which they were recorded, press the IN key continuously for about 3
seconds. This will reset all minimum and maximum data recorded to the
current time, date, temperature and humidity. The min/max temperatures
recorded are of current time and they remain unaffected by the time zone
setting.
LCD 4 OUTDOOR TEMPERATURE:
Outdoor Temperature
in °C
The fourth LCD section shows the outdoor temperature and a transmission signal.
A number besides the temperature will also show if more than one transmitter is
used.
TOGGLING AND RESETTING THE OUTDOOR RECORDINGS:
1.
To toggle between the outdoor current, minimum and maximum temperature
Indoor Relative Humidity %
data and the times at which they were recorded, press the OUT key:
Once to show the minimum temperature value with time and date recorded
Twice to show the maximum temperature value with time and date recorded
Three times to return to the current time, date and temperature level
2.
To toggle between transmitters, press the CH key:
Once to show transmitter 2
Twice to show transmitter 3
Three times to return to transmitter 1
Note: The transmitter number will only be displayed if there is more than one
transmitter detected.
3.
To reset the minimum and maximum temperature data and the times at which
:
they were recorded, press the OUT key continuously for about 3 seconds.
This will reset all minimum and maximum data recorded to the current time,
date and temperature. The min/max temperature recorded are of current time
and they remain unaffected by the time zone setting.
TEMPERATURE TRANSMITTER:
Outdoor Temperature
The LCD display shows the current temperature at the location of the transmitter.
The temperature is measured and transmitted to the Temperature Station
approximately every 60 seconds and at each transmission the antenna icon (Y) will
light briefly.
Maximum Display
Outdoor Transmission Signal
Number showing the
transmitter unit (only if
there is more than one
transmitter

Publicidad

Tabla de contenido
loading

Tabla de contenido