Explosion Hazard
Keep flammable
materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need
•
A location that allows for proper exhaust installation. A gas
dryer must be exhausted to the outdoors. See "Venting
Requirements."
•
A grounded electrical outlet located within 2 ft (61 cm) of
either side of the dryer. See "Electrical Requirements."
•
A sturdy floor to support the dryer with a total weight (dryer
and load) of 200 Ibs (90.7 kgs). The combined weight of a
companion
appliance should also be considered.
•
A level floor with a maximum slope of 1 in. (2.5 cm) under
entire dryer. (If slope is greater than 1 in. [2.5 cm], install
Extended Dryer Feet Kit, Part Number 279810.) Clothes may
not tumble properly and dryers with automatic sensor cycles
may not operate correctly if dryer is not level.
Do not operate your dryer at temperatures
below 45°F (7°C). At
lower temperatures,
the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements.
Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning
appliance can be installed in the
same closet as a dryer.
Installation
Clearances
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
1EM"
,74om)
/
2
4
t3_"
1. Small Opening Side-Swing
Door
2. Large Opening Side-Swing
Door
3. Wide Opening Side-Swing
Door
4. Wide Opening Hamper Door
*Most installations require a minimum 5t/2 in. (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Minimum
installation
spacing for recessed area or closet
installation
The dimensions shown following are for the minimum spacing
allowed.
•
Additional spacing should be considered for ease of
installation and servicing.
•
Additional clearances might be required for wall, door and
floor moldings.
•
Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is
recommended
to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.