AC input voltage --------------------------------------------------------------------------- ±10% of rated line voltage
Acceleration ------------------------------------------------------------------------------ 0.5 seconds standard 125D
Amps - DC output; (Models 130XX12 & 132XX25) -------------------------------------- 500 mA to 1.2 ADC
(Models 130LC100 & 132LC200) ----------------------------------- 500 mA to 5.5 ADC*
(Models 130HC100 & 132HC200) ----------------------------------- 500 mA to 10 ADC
Controller overload capacity ------------------------------------------------------------------- 200% for one minute
Current limit trimpot range; (Models 130XX12 & 132XX25) ------------------------------------ 0.3 to 3 ADC
Deceleration
Dimensions and weights:
LC MODELS
ENGLISH
METRIC
HC MODELS
ENGLISH
METRIC
Drive service factor ------------------------------------------------------------------------------------------------------ 1.0
Efficiency ------------------------------------------------------------------------------------------------------- 85% typical
Input frequency -------------------------------------------------------------------------------------------- 50 or 60 Hertz
Max. trimpot speed range ------------------------------------------------------------ 60% to 110% of base speed
Min. trimpot speed range ---------------------------------------------------------- 0% to 30% of maximum speed
Power devices ---------------------------------------------------------------------------------------- isolated case tab
Shunt field voltage --------------------------------- 100VDC for 120VAC input; 200VDC for 240VAC input
Shunt field current ------------------------------------------------------------------------------- 1 amp DC maximum
Speed control --------------------------------- via 5Kohms .5W potentiometer or 0-10VDC isolated signal
Speed range ------------------------------------------------------------------------------------------------------------- 50:1
Speed regulation ---------------------------------------------------------------------------------- ±1% of base speed
Temperature range ------------------------------------------------------- -10° to 45° C. ambient (15° to 115° F.)
Terminal Block Torque Setting -------------------------------------------------------------- 4.4 in. lb. Max or .5Nm
Transient protection ------------------------------------------------------------------------------------------------ G-Mov
Trigger --------------------------------------------------------------------------------------------------------- opto-isolator
Start/Brake cycle per minute (LC Models) ---------------------------------------------------------------- 3 per min**
Approval -------------------------------------------------------------------------------------------------------
* With suitable external heatsink (where 130 extrusion temperature does not exceed 70° C.), maximum rating for output amps
can be increased to 10 amps D.C.
** Cycles per minute are based on typical inertia type loads. Higher cycle per minute rates may be achieved with constant
torque or low inertia type loads. Lower cycle rates may be required for very high inertia type loads.
Horsepower
Typical AC Amps (120VAC)
Typical Arm Amps (120VAC)
Typical AC Amps (240VAC)
Typical Arm Amps (240VAC)
SPECIFICATIONS
(Models 130XX100 & 132XX200) ---------------------------------- 1 to 18 ADC
W
4.967"
126.16mm
107.95mm
W
6.250"
158.75mm
177.80mm
(HC Models) --------------------------------------------------------------- 30 per min**
TYPICAL MOTOR CURRENTS
1/50
1/20
1/8
0.50
1.00
1.60
0.42
0.81
1.20
-----
0.80
0.90
-----
0.40
0.60
0.5 seconds (standard 125D)
L
D
4.250"
2.688"
68.27mm
L
D
7.000"
4.063"
103.20mm
1/4
1/3
1/2
3/4
3.50
4.40
6.50
9.30
2.70
3.40
5.00
8.20
1.80
2.20
3.30
4.80
1.40
1.70
2.50
3.70
10
WEIGHT
1.08lb.
489.87g
WEIGHT
3.30lb.
1496.80g
1.0
1.5
2.0
13.20
-----
-----
10.90
-----
-----
6.50
9.70
12.90
5.00
8.20
11.60