(1) DISCONNECT
STAPLER.
REMOVE ALL STAPLES FROM STAPLER.
ALL SCREWS MUST BE TIGHTENED.
If any screws are loose, tighten them.
THE PUSH LEVER AND TRIGGER
MUST MOVE SMOOTHLY.
Push
lever
(2) Adjust the air pressure to 70 psi (4.9 bar
5 kgf/cm
2
).
Connect the air hose.
Do not load any staples in the Stapler.
THE STAPLER MUST NOT LEAK AIR.
Hold the Stapler downward and pull the
trigger.
AIR
HOSE
FROM
Trigger
Do not connect
air hose
THE STAPLER MUST NOT OPERATE.
Push lever
(3) With finger off the trigger, depress the
push lever against the workpiece.
THE STAPLER MUST NOT OPERATE.
Depress
push lever
(4) Without touching the trigger, depress the
push lever against the workpiece.
Pull the trigger.
THE STAPLER MUST OPERATE.
(5) With the Stapler off the workpiece, pull
the trigger.
Depress the push lever against the
workpiece.
THE STAPLER MUST OPERATE.
(6) If no abnormal operation is observed, you
may load staples in the Stapler.
Drive staples into the workpiece that is
the same type to be used in the actual
application.
THE STAPLER MUST OPERATE
PROPERLY.
— 13 —
English
Pull trigger
Do not pull trigger