Performance
Data Sheet
SmartWater Filtration System
MWF Cartridge
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration
of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*
'100% safety factors built in for unmetered usage)
Standard
No. 42: Aesthetic
Effects
Parameter
Chlorine
T&O
Particulate**
USEPA
MCL
Influent
Challenge Concentration
2.0 mg/L ± 10%
_> 10,000 particlesimL
Influent
Average
1.96mg/L
6,400,000 #/mL
Effluent
Average
Maximum
0.06 mg/L
0.11 mg/L
58,833 #/mL
150,000 #/mL
Standard
No. S3: Health Effects
Parameter
Influent
Challenge Concentration
11+ 1NTU***
Hinimum50,000L
107 to 108fibers!L; > 10ym
0.15rng/L+ 10%
0.15rng/L+ 10%
0.006mg/L+ 10%
0.006mg/L+ 10%
0.04mg/L+ 10%
0.002mg/L+ 10%
0.210rng/L+ 10%
0.015rng/L+ 10%
0.015rng/L+ 10%
0.080mg/L+ 10%
0.225rng/L+ 10%
0.009rng/L+ 10%
USEPA
MCL
0.5 NTU
Turbidity
Cysts
> 99.95% Reduction
Asbestos
> 99% Reduction
Lead at pH 6.5
0.015 mg/L
Lead at pH 8.5
0.015 mg/L
Mercury at pH 6.5
0.002 mg/L
Mercury at pH 8.5
0.002 mg/L
Alachlor
0.002 mg/L
Lindane
0.0002 mg/L
2,4-D
0.070 mg/L
Toxaphene
0.003 mg/L
Benzene
0.005 mg/L
Carbofuran
0.040 mg/L
1,4dichlorobenzene
0.075 mg/L
Atrazine
0.003 mg/L
Influent
Average
10.5 NTU
118,750 #/L
57 HF/L
0.1567 mg/L
0.1433 mg/L
0.0059 mg/L
0.0057 mg/L
0.0367 mg/L
0.0020 mg/L
0.2033 mg/L
0.0160 mg/L
0.0145 mg/L
0.0830 mg/L
0.2283 mg/L
0.0087 mg/L
Effluent
Average
Maximum
0.14 NTU
0.28 NTU
<I#/L
4#/L
0.996 HF/L
< i HFiL
< 0.001 mg/L
< 0.001 mg/L
< 0.001 mg/L
< 0.001 mg/L
0.000350 mg/L
0.0007 mg/L
0.000325 mg/L
0.0006 mg/L
0.00023 mg/L
0.0004 mg/L
< 0.00002 mg/L
< 0.00002 mg/L
0.00337 mg/L
0.011000mg/L
0.00100 mg/L
0.001000 mg/L
0.000500 mg/L
0.000500 mg/L
0.001000 mg/L
0.001000 mg/L
0.000500 mg/L
0.000500 mg/L
< 0.0005 mg/L
< 0.0005 mg/L
%Reduction
Average
Minimum
96.77%
94.74%
99.14%
97.97%
%Reduction
Average
Minimum
98.54%
97.20%
> 99.99%
> 99.99%
99.60%
99.39%
99.36%
99.29%
99.30%
99.29%
94.70%
87.50%
93.20%
89.29%
99.34%
98.67%
99.00%
98.95%
98.32%
94.50%
93.44%
91.67%
96.51%
95.83%
98.78%
98.65%
99.78%
99.77%
94.22%
93.33%
Min. Required
Reduction
> 50%
> 85%
Min. Required
Reduction
0.5 NTU
_> 99.95%
_> 99%
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.070 mg/L
0.003 mg/L
0.005 mg/L
0.04 rng/L
0.075 mg/L
0.003 mg/L
Tested using a flow rate of 0.50 gpm; pressure
of 60 psig; pH of 7.5 +_0.5; temp. of 68 ° ++_ 5°F (20 ° ++_ 3°C)
** Measurement
in Particles/ml.
Particles used were 0.5-1 microns
*** NTU=Nephelometric
Turbidity
units
Operating
Specifications
• Capacitg: certified for up to 300 gallons (1135 I); up to six months for models without a replacement filter indicator light;
up to one gear for models with a replacement filter indicator light
• Pressure requirement: 40-120 psi (Z8-&2 bar), non-shock
• Temperature: 33-100°F (0.5-38°C)
• Flow rate: 0.5 gpm (1.9 Ipm)
General Installation/Operation/Maintenance Requirements
• Flush new cartridge at full flow for 3 minutes to purge out trapped ain
• Replace cartridge when the indicator light flashes or water flow rate is reduced on non-indicator units.
Special Notices
• Installation instructions, parts and service availabilitg, and standard warrantg ore included with the product when shipped.
• This drinking water sgstem must be maintained according to manufacturer's instructions, including replacement of filter cartridges.
• Do not use with water that is microbiologicallg unsafe or of unknown qualitg without adequate disinfection before or after
the sgstem. Sgstems certified for cgst reduction mag be used on disinfected water that mag contain filterable cgsts.
• The contaminants or other substances removed or reduced bg this water treatment sgstem are not necessarilg in gout wateE
• Check for compliance with the state and local laws and regulations.
• Note that while the testing was performed under standard laboratorg conditions, actual performance mag varg. Sgstems must
be installed and operated in accordance with manufacturer's recommended procedures and guidelines.
Standard No. 42: Aesthetic Effects
Chemical Unit
Chlorine Taste and Odor
Mechanical Filtration Unit
Particulate Reduction, Class I
Sgstem Tested and Certified bg NSF International against ANSI/NSF Standard 42 & 53 for the reduction of:
Standard No. $3: Health Effects
Chemical Reduction Unit
Alachlor and Atrazine Reduction
Benzene and Carbofuran Reduction
1,4 dichlorobenzene and 2,4-D Reduction
Lead and Lindane Reduction
Mercurg and Toxaphene Reduction
Mechanical Filtration Unit
Turbiditg Reduction
Cgst and Asbestos Reduction
Manufactured for: General Electric Compang, Louisville, KY40225
EPA EST.No. 070S9S-MN-O01
39