22. Correction of Malfunctions
Malfunction
No coating
material emerges
from the nozzle
Coating material
drips from the
nozzle
Atomisation too
coarse
Spray jet pulsates
Coating material
causes "paint
tears"
12
Cause
•
Nozzle clogged
•
Material volume setting too low
•
No pressure build-up in container
•
Container empty
•
Feed tube loose
•
Feed tube clogged
•
Coating material clogged at air cap,
nozzle or needle
•
Nozzle loose
•
Nozzle seal worn
•
Nozzle worn
•
Material volume too high
•
Nozzle contaminated
•
Viscosity of coating material too
high
•
Too little pressure build-up in
container
•
Air filter heavily soiled
•
Amount of air too low
•
Coating material in container
running out
•
Nozzle seal worn
•
Air filter heavily soiled
•
Too much coating material applied,
material volume setting too high
HV2901/3901/5901
Remedy
➞ Clean
➞ Alter material volume
adjuster
➞ Tighten container
➞ Refill
➞ Insert
➞ Clean
➞ Clean
➞ Tighten air cap ring
➞ Change
➞ Change
➞ Alter material volume
adjuster
➞ Clean
➞ Dilute further
➞ Tighten container
➞ Change
➞ Alter material volume
adjuster
➞ Refill
➞ Replace
➞ Replace
➞ Alter material volume
adjuster